Junkers Euromaxx Circulating Pump ZWC 28/32-1 MFA Ref. 8716771427
RefurbishedJunkersPumps

Junkers Euromaxx Circulating Pump ZWC 28/32-1 MFA Ref. 8716771427

50 €VAT includedIn stock · 1 unit

Circulating pump: reconditioned spare part that circulates water in the heating circuit. Useful if there is noise, water is not circulating, or radiators do not heat evenly. Compatible with ZWC 24-1 MF2A (ref. 8716771427). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
8716771427
Brand
Junkers
Type of part
Pumps
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 8716771427) equips these models. Verified compatibility; check the reference before purchasing.

Junkers Euromaxx ZWC

  • ZWC 24-1 MF2A

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
E9The STB has been activated.If the circulating pump is blocked or has no flow, the primary overheats and triggers the safety limiter (STB); check by powering the Grundfos UPS 15-60 RLE, confirming rotation/consumption and bleeding the circuit to remove air.
AAExcessive temperature difference between the heating flow circuit and the domestic hot water.A stopped/blocked pump causes a large ΔT between flow and DHW; check start-up in test mode, flow through bypass, and ensure the rotor is not jammed and there is no air in the system.
How do I know if this circulating pump is the one for my boiler?
Verify the reference 8716771427 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Grundfos piece.
What is it used for?
The circulating pump circulates the water through the heating circuit.
Noise, water not circulating, or cold radiators?
Typical symptoms: humming, seized rotor after a long stop, or radiators that do not heat evenly.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Bleed the air from the circuit and the pump; check the pressure at 1–1.5 bar with the boiler cold.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Euromaxx ZWC 28/32-1 MFA

Scroll to the top