Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.75Pump error/lack of water: no pressure increase detected when the pump starts.The circulator 0020023217 is blocked or faulty and does not generate the pressure increase that the sensor should read; check by activating the pump directly (rotation/consumption) and observing the pressure sensor value during the pre-start.
F.23Safety shutdown: excessive flow/return temperature variation (lack of circulation).If the 0020023217 does not provide flow (blocked or with reduced power), the flow heats up much faster than the return; check the pump's consumption/rotation and the ΔT in diagnostics.
F.24Safety shutdown: temperature rise too fast due to lack of circulation.The fault of the 0020023217 causes a sudden rise in temperature in the primary; check that the pump is rotating and providing flow (bleed/diagnostic mode) and that there is no air in the circuit.
F.20Safety shutdown: temperature limiter (heat exchanger overheating).With the 0020023217 blocked or without performance, the water does not circulate and the heat exchanger overheats until the limiter trips; check pump rotation/consumption, bleed, and confirm actual flow rate.