Chaffoteaux Expansion Vessel MC2 24 FF Ref. 60056676 06
Expansion Vessel Chaffoteaux MC2 24 FF Ref. 60056676, designed to absorb the increase in water volume when heated. When this part fails, you may notice that the boiler pressure rises and falls sharply, and the safety valve may leak. This expansion vessel is compatible with several models, including the CALYDRA DELTA 24 FF, CELTIC 2.20 FF RSC, CENTORA 2.24 FF, ELEXIA COMFORT 24 FF, MC 2 24 FF, and NECTRA COMFORT 2.24 FF, among others. A technician must confirm through diagnosis whether it is necessary to replace it when the mentioned pressure irregularities are detected.
Compatible Chaffoteaux boilers
Expansion vessel. Seven confirmed compatibilities: DELTA 24 FF and 2.20 FF RSC.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux DELTA 24 FF | CALYDRA | Contrasted |
| Chaffoteaux 2.20 FF RSC | CELTIC | Contrasted |
| Chaffoteaux 2.24 FF | CENTORA | Contrasted |
| Chaffoteaux COMFORT 24 FF | ELEXIA | Contrasted |
| Chaffoteaux 2 24 FF | MC | Contrasted |
| Chaffoteaux COMFORT 2.24 FF | NECTRA | Contrasted |
| Chaffoteaux DELTA 24 FF | NIAGARA | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the expansion vessel
The expansion vessel absorbs the expansion of water when heated. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure suddenly rises as soon as the heating is turned on and then gradually decreases.
Cause: The vessel does not cushion the expansion of the water well, and the entire increase in volume is suddenly reflected on the pressure gauge.
Check that the radiator bleed valves are not air-locked before declaring the vessel empty; air in the circuit has a similar effect.
- 02
There are noticeable knocks in the pipes when starting the pump or when closing the thermostatic valves.
Cause: Without the cushioning of the expansion vessel, sudden pressure changes are transmitted as water hammer through the system.
Check that the thermostatic valves do not close abruptly and that the automatic air vents are functioning before replacing the expansion vessel.
- 03
The water circuit needs to be refilled every few days even though no leaks are visible.
Cause: The pre-charge air in the expansion vessel has escaped, and the system compensates for that lack of cushioning by taking in more water than necessary.
Check the bleed valves, fittings, and the filling valve itself for any leaks: a small leak produces the same symptoms as an empty expansion vessel.
- 04
Does the glass sound different when gently tapped on the top and bottom, or does it sound the same across its entire surface?
Cause: In a healthy vessel, there is an area with air (it sounds hollow) and another with water; if it sounds the same throughout, it may be full of water due to membrane rupture.
Compare the sound when tapping the top and bottom of the tank with the boiler cold before deciding on the replacement.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Chaffoteaux expansion vessel datasheet
- Uniclima internal SKU
- VECMC224FF
- Brand
- Chaffoteaux
- Type of part
- Expansion vessels
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- maximum pressure
- 3 bar