Expansion Vessel Chaffoteaux Niagara Delta 30 FF

Expansion Vessel Chaffoteaux Niagara Delta 30 FF

Stock · 1 unit

Expansion vessel Chaffoteaux Niagara Delta 30 FF, reference 60056676-06. This component is responsible for absorbing the increase in water volume when heated. If it has faults, such as loss of charge or a broken diaphragm, you will notice that the boiler pressure fluctuates sharply, and the safety valve may leak. It is compatible with boilers from the Aludra, Calydra, Celtic, Centora, Elexia, and Nectra ranges, among others. It is recommended to replace it when these symptoms are detected to avoid larger issues.

VAT included

Compatibility

Compatible Chaffoteaux boilers

Expansion vessel. Nine confirmed compatibilities: Delta 24 FF and Delta 28 FF.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux Delta 24 FFAludraContrasted
Chaffoteaux Delta 28 FFAludraContrasted
Chaffoteaux 2.23 FFCalydraContrasted
Chaffoteaux 2.28 FFCalydraContrasted
Chaffoteaux 1.16 RSCCelticContrasted
Chaffoteaux 2.24 FFCentoraContrasted
Chaffoteaux Comfort 24 FFElexiaContrasted
Chaffoteaux 2.23 FFNectraContrasted
Chaffoteaux Delta 30 FFNiagaraContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the expansion vessel resolves

The expansion vessel absorbs the expansion of water when heated. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The circuit is gradually losing pressure, and you have to refill more frequently than usual.

    Cause: The vessel has lost its air charge or has a leak in the membrane and no longer retains the pressure that it should maintain in the circuit.

    Measure the pre-charge pressure of the vessel when cold and without water in the circuit: the label on this part indicates a setting of 3 bar, so if it measures well below that, it confirms the loss.

  • 02

    The safety valve is leaking or repeatedly discharging water, especially when the boiler is running.

    Cause: If the expansion vessel does not absorb the expansion of the hot water, the pressure rises until the safety valve releases it.

    Before changing the expansion vessel, check that the safety valve is not simply dirty or damaged at its seat; a valve that does not close properly will leak just the same with a vessel in good condition.

  • 03

    The glass sounds full, without the characteristic air gap, when tapped with the hand.

    Cause: A broken membrane allows water to pass to the air side, and the vessel ends up behaving like an additional section of filled pipe.

    With the depressurized system, tap the tank at different points; if the sound is uniform and solid across the entire surface, there is no air inside.

  • 04

    The pressure rises significantly just when starting the heating and drops when it stops.

    Cause: It is the typical signature of a vessel without expansion capacity: all the volume of water that expands goes directly to circuit pressure.

    Compare the cold pressure with the pressure a few minutes after operation; a large and repeated difference points to the expansion vessel, although it is advisable to rule out excessive filling first.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Chaffoteaux expansion vessel datasheet

Brand
Chaffoteaux
Type of part
Expansion vessels
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Set pressure
3 bar
Frequently Asked Questions

Frequently asked questions about the expansion vessel

Is this expansion vessel suitable for a Chaffoteaux Elexia Comfort 24 FF?
Yes, it is on the list of compatible boilers along with the models from the Aludra, Calydra, Celtic, Centora, Nectra, and Niagara ranges.
What pressure is the expansion vessel of the Niagara Delta 30 FF set to?
The label confirms a set pressure of 3 bar.
When should the expansion vessel of the Celtic 1.16 RSC be replaced?
It is replaced when it loses pressure or leaks from the safety valve.
What is the reference for the expansion vessel for the Niagara Delta 30 FF?
The reference is VDEND30FF.
How many boiler models are compatible with the expansion vessel VDEND30FF?
There are a total of 9 confirmed models.
Is this expansion vessel compatible with the Chaffoteaux Nectra 2.23?
Yes, the expansion vessel is compatible with the Chaffoteaux Nectra 2.23.