Combustion Gas Extractor Fan Junkers Euromaxx ZWC 28 32 1MFA 23 Ref. 8716772508

Combustion Gas Extractor Fan Junkers Euromaxx ZWC 28 32 1MFA 23 Ref. 8716772508

50 €VAT includedIn stock · 1 unit

Extractor: reconditioned spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with ZWC 24/28-1MFA, ZWC 28/32-1MFA (ref. 8716772508). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
8716772508
Brand
Junkers
Type of part
Extractors
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 8716772508) equips these models. Verified compatibility; check the reference before purchasing.

Junkers Euromaxx ZWC

  • ZWC 24/28-1MFA
  • ZWC 28/32-1MFA

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
C7No fan speed signal.The fan/extractor does not deliver the tachometer signal to the Heatronic (motor/rpm sensor or wiring). Check by measuring the speed signal at the fan connector and the power supply/continuity.
C6The pressure switch does not close.If the fan does not start or does not generate sufficient depression, the differential pressure switch does not close and the boiler locks out. Check that the fan rotates and reaches rpm and measure the depression at the pressure switch ports with a U-tube manometer.
CATurbine revolutions too high.The fan operates above the allowed range (fault of the motor itself/rpm control) and the Heatronic detects overspeed. Verify the tachometer signal and the control–rpm correlation according to service values.
C1The pressure switch has activated during operation.Flow drop or intermittent fan stoppage causes the pressure switch to open during operation. Check the fan's consumption and rpm under load and rule out obstructions/friction in the extractor group–chimney.
How do I know if this extractor/fan is the one for my boiler?
Verify the reference 8716772508 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Euromaxx ZWC 28 32 1MFA 23

Scroll to the top