Vaillant Extractor VCM 182 Ref. 0020073797

Vaillant Extractor VCM 182 Ref. 0020073797

85 €VAT includedIn stock · 1 unit

Extractor: reconditioned spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with VM 242 E, VMW 182 E, VMW 242 E (ref. 0020073797). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
0020073797
Brand
Vaillant
Type of part
Extractors
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 0020073797) equips these models. Verified compatibility; check the reference before purchasing.

ATMOBLOCK (E)

  • VM 242 E
  • VMW 182 E
  • VMW 242 E
  • VMW 282 E

TURBOBLOCK (/1 E)

  • VM 242/1 E
  • VM 282/1 E
  • VMW 182/1 E
  • VMW 242/1 E
  • VMW 282/1 E

VCM

  • VCM 182 E
  • VCM 182/1 E
  • VCM 242/1 E
  • VCM 282/1 E

VC

  • VC 242 E
  • VC 242/1 E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.32Fan fault: defective or not connected fan.The VCM 182 extractor does not start or does not deliver Hall rpm signal to the PCB (motor blocked, loose connector/wiring, or damaged winding). Check power supply voltage and Hall signal at the fan connector and ensure the impeller spins freely.
F.37The fan speed during operation is too high or too low.The VCM 182 extractor does not maintain speed within tolerance (seized bearings, motor defects, or Hall sensor issues). Check rpm in diagnostics, fan condition, and wiring; if the issue persists, measure Hall signal and motor consumption.
F.38Fan short circuit.Electrical short in the VCM 182 extractor motor or its wiring harness causes detection of 'ventilatorkurzschluss'. Check motor insulation, continuity/derivations of the harness, and consumption when powered.
How do I know if this extractor/fan is the one for my boiler?
Verify the reference 0020073797 printed and ensure your model is on the list of compatibles; also compare the connections with the original part. It is an RLA part (RLA 108/0034 A82-3030LH, 230V 54W).
What is it used for?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.