Vaillant Fan Extractor Turbotec ES 242 2 5 Fime GR00885B Ref. 190215

Vaillant Fan Extractor Turbotec ES 242 2 5 Fime GR00885B Ref. 190215

75 €VAT includedIn stock · 4 units

Extractor: refurbished spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with VMW 242-3, VMW 242-5, VMW 242/2-3 (ref. 190215). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
190215
Brand
Vaillant
Type of part
Extractors
Available units
4 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 190215) equips these models. Verified compatibility; check the reference before purchasing.

Turbo Tec / VMW ES (combi)

  • VMW 242-3
  • VMW 242-5
  • VMW 242/2-3
  • VMW 242/2-5
  • VMW 242/2-5 R1
  • VMW 282-5
  • VMW 282/2-5

Turbo Tec / VM ES (heating only)

  • VM 202-5
  • VM 242-5
  • VM 282-5
  • VM 202/2-5
  • VM 242/2-5
  • VM 282/2-5

TurboMax Plus / TurboMax Pro

  • TurboMax Plus 824E
  • TurboMax Pro

ThermoCompact

  • ThermoCompact

VMI (sealed interior)

  • VMI 282-7

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.32Fault: fanThe extractor fan does not start, is blocked, or does not deliver a Hall signal; the electronics detect absence/anomaly of rpm. Check 230 V at the connector, continuity of the harness, and rpm/Hall signal reading in diagnostics.
F.33The pressure switch (manometric capsule) does not turn on.If the fan does not generate sufficient depression, the air pressure switch does not switch, and the unit locks out. Check that the fan is running at the correct speed and that the pressure switch closes with the fan running (hoses, wiring, and contacts).
F.37Divergence of the number of revolutions during operationThe fan delivers a number of revolutions inconsistent with the setpoint (defective motor/Hall sensor or blockage), and the electronics detect the discrepancy. Verify actual vs. nominal rpm in diagnostics and mechanical condition/signal of the fan.
How do I know if this extractor/fan is the one for my boiler?
Verify the reference 190215 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Fime part.
What is it used for?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.