SIT 504 Spark Train NAC 0604016-09 - Fagor Contract CE 20E 1N
Refurbished Fagor Gas burners SIT

SIT 504 Spark Train NAC 0604016-09 - Fagor Contract CE 20E 1N

SIT 504 NAC ignition component, code 0604016-09, from the gas burner of Fagor Contract CE 20E 1N and FEB 20E boilers. Confirmed manufacturer: SIT. It operates at 230V, 50/60Hz. The replacement requires first confirming the fault of the part through technical diagnosis, even when the burner ignition fails or the boiler does not start.

Type of part
Gas burners
internal SKU
TDCHCCE20E
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Compatible Fagor boilers

Burner. Three confirmed compatibilities: CE20E1N and FEB20E1N.

Proven compatibility

Boiler modelFamilyVerification
Fagor CE20E1NCE20E1NContrasted
Fagor FEB20E1NFEB20E1NContrasted
Fagor FEB20EF1GLPFEB20EF1GLPContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the burner

The burner performs the combustion of gas. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite but does not generate a spark and locks out after a few seconds.

    Cause: The spark train does not produce the necessary arc to ignite the pilot flame or the main burner.

    Look through the peephole to see if there is a spark at the electrode when starting; if there is nothing, first check the high voltage cable and its connection.

  • 02

    A strange clicking or buzzing sound is heard in the burner just before the boiler locks out.

    Cause: The ignition component fails intermittently and generates an irregular arc instead of a clean spark.

    Check that the electrode is clean and has the correct gap, and that it is not touching the ground, before declaring the part defective.

  • 03

    The boiler locks out in cold due to ignition failure and needs to be reset every time.

    Cause: Without a reliable spark, the control board does not detect flame within the safety time and cuts off the gas supply.

    Also check the gas supply and the condition of the gas valve before replacing the spark electrode assembly: the symptom is similar in both cases.

  • 04

    Sometimes it ignites on the first try and other times it gets blocked, without a clear pattern.

    Cause: The spark train fault is intermittent, typical of moisture, dirt, or internal degradation of the component.

    Repeat the cold start three or four times in a row and note if the fault occurs consistently or only sometimes.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Fagor burner datasheet

Uniclima internal SKU
TDCHCCE20E
Brand
Fagor
Type of part
Gas burners
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
SIT
Reference code
SIT 504 NAC 0604016-09
Nominal voltage
230 V
Frequency
50/60 Hz
Frequently Asked Questions

Frequently asked questions about the burner

Who manufactures the spark generator for the Fagor Contract CE 20E 1N?
SIT, confirmed by the label and external sources.
What code does this SIT 504 NAC spark train have?
SIT 504 NAC, code 0604016-09.
What voltage does the spark generator of the Fagor FEB 20E 1N operate at?
A 230V, 50/60Hz, according to the label.
Is this spark electrode suitable for the Fagor FEB 20E F1 GLP?
Yes, the FEB 20E F1 GLP is on the list of compatible boilers for this part.
What fault does replacing this spark train in the Fagor Contract CE 20E 1N resolve?
It should be checked when the burner ignition fails or the boiler does not start. Replacement requires a technical diagnosis.
Is this spark electrode the same as other parts with the model SIT 504 NAC?
The base model SIT 504 NAC is the same, but the complete code may vary; it is advisable to check the code of your part.

Spare parts related to Fagor CE20E1N

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
SIT 504 Spark Train NAC 0604016-09 - Fagor Contract CE 20E 1N