SIT 504 Spark Train NAC 0604016-09 - Fagor Contract CE 20E 1N
SIT 504 NAC ignition component, code 0604016-09, for the gas burner of Fagor Contract CE 20E 1N and FEB 20E boilers. Manufacturer confirmed: SIT. Operates at 230V, 50/60Hz. It is replaced when the burner ignition fails or the boiler does not start.
VAT included
Consult via WhatsAppCompatible Fagor boilers
Burner. Three confirmed compatibilities: CE20E1N and FEB20E1N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor CE20E1N | CE20E1N | Contrasted |
| Fagor FEB20E1N | FEB20E1N | Contrasted |
| Fagor FEB20EF1GLP | FEB20EF1GLP | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the burner resolves
The burner performs the combustion of gas. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite but does not generate a spark and locks out after a few seconds.
Cause: The spark train does not produce the necessary arc to ignite the pilot flame or the main burner.
Look through the peephole to see if there is a spark at the electrode when starting; if there is nothing, first check the high voltage cable and its connection.
- 02
A strange clicking or buzzing sound is heard in the burner just before the boiler locks out.
Cause: The ignition component fails intermittently and generates an irregular arc instead of a clean spark.
Check that the electrode is clean and has the correct gap, and that it is not touching the ground, before declaring the part defective.
- 03
The boiler locks out in cold due to ignition failure and needs to be reset every time.
Cause: Without a reliable spark, the control board does not detect flame within the safety time and cuts off the gas supply.
Also check the gas supply and the condition of the gas valve before replacing the spark electrode assembly: the symptom is similar in both cases.
- 04
Sometimes it ignites on the first try and other times it gets blocked, without a clear pattern.
Cause: The spark train fault is intermittent, typical of moisture, dirt, or internal degradation of the component.
Repeat the cold start three or four times in a row and note if the fault occurs consistently or only sometimes.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Fagor burner datasheet
- Brand
- Fagor
- Type of part
- Gas burners
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- SIT
- Reference code
- SIT 504 NAC 0604016-09
- Nominal voltage
- 230 V
- Frequency
- 50/60 Hz