Fagor Gas Valve CE 24E N SIT Ref. MU0809100
RefurbishedFagorGas valves

Fagor Gas Valve CE 24E N SIT Ref. MU0809100

65 €VAT includedIn stock · 5 units

Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with FE-20E/2N, FE-20E/2B, FE-20E (ref. MU0809100). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
MU0809100
Brand
Fagor
Type of part
Gas valves
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. MU0809100) equips these models. Verified compatibility; check the reference before purchasing.

Fagor Eco Compact FE-20E

  • FE-20E/2N
  • FE-20E/2B
  • FE-20E

Fagor FE (rest of series)

  • FE-24E
  • FE-27E
  • FE-24NOX

Fagor FA

  • FA-20E2N
  • FA-23EN

Fagor FEB

  • FEB-20E

Fagor FEE

  • FEE-20

Fagor CA

  • CA-20EN

Fagor CE

  • CE-20E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F1Lockout due to ignition fault (flame not established).The faulty/stuck gas valve may not open or modulate at startup, and insufficient gas may reach for ionization; check voltage in coils during the ignition attempt and pressure/flow in the ramp, ensuring the valve opens.
F6Flame detection with the burner at rest (parasitic flame).If the gas valve does not close hermetically, it allows gas to pass and a residual flame persists; check the valve's closure/sealing when stopped and rule out a false ionization signal.
F10Fault in the control or closure of the gas valve.Fault in the valve or its control circuit (coils/relays) prevents proper opening/closing; check coil continuity, control voltage from the PCB, and ensure the flame extinguishes when closure is commanded.
How do I know if this gas valve is the one for my boiler?
Verify the reference MU0809100 printed and ensure your model is on the list of compatibles; also compare the connections with the original part. It is a SIT part.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler CE 24E N SIT