Gas Solenoid Valve Vaillant VMW ES 282 2 5 Turbomax Plus Turbotec Ref. 053462

Gas Solenoid Valve Vaillant VMW ES 282 2 5 Turbomax Plus Turbotec Ref. 053462

55 €VAT includedIn stock · 5 units

Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with VMW 240-3, VMW 240-5, VMW 242-3 (ref. 053462). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
053462
Brand
Vaillant
Type of part
Gas valves
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 053462) equips these models. Verified compatibility; check the reference before purchasing.

turboTEC / turboTEC plus (VMW turbo)

  • VMW 240-3
  • VMW 240-5
  • VMW 242-3
  • VMW 242-5
  • VMW 280-5
  • VMW 282-5
  • VMW 240/2-5
  • VMW 242/2-5
  • VMW 282/2-5

atmoTEC / atmoTEC plus (VM open chamber)

  • VM 202-5
  • VM 240-5
  • VM 242-5
  • VM 280-5
  • VM 282-5
  • VM 240/2-5
  • VM 282/2-5

VMI

  • VMI 280-7
  • VMI 282-7
  • VMI 32/362-7

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.26Fault: gas valve not functioning.The stepper motor/coils of the gas valve (SIT 053462) are open, shorted, or disconnected, so the valve does not operate; check coil resistance/insulation and stepper motor signal/return from the PCB during the ignition attempt.
F.61Gas valve activation error.The gas valve cannot be operated due to an internal fault (coils shorted/ground leakage) or wiring failure; confirm by measuring the resistance/insulation of coils, wiring harness, and control signal from the PCB.
F.62Gas valve disconnection delay.The gas valve remains stuck/not sealed and takes time to close, maintaining the flame signal after the closure command; check for tightness and closing time (ionisation/analyser) and rule out internal leakage of the valve assembly.
F.28The appliance does not start: failed ignition attempts during startup.The gas valve does not open or is incorrectly adjusted, preventing flow during ignition; check inlet pressure, control signal, and actual valve opening during the ignition sequence.
F.29The flame goes out during operation and subsequent ignition attempts fail.Intermittent fault of the gas valve (flow drop/leakage when hot) causes flame loss; check pressure stability and valve operation under load and confirm by replacing/adjusting the valve assembly if necessary.
How do I know if this gas valve is the one for my boiler?
Verify the reference 053462 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a SIT part.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler VMW ES 282 2 5 Turbomax Plus Turbotec