| F.28 | Start-up fault: ignition failed | If THIS gas valve (0020146733) does not open or is misadjusted (offset/calibration), insufficient gas reaches the burner during ignition. Check voltage/control at the connector, adjustment of the gas block, and pressures at test points during the ignition test. |
| F.29 | Ignition and control error during operation, the flame is off. | A faulty or poorly modulated gas valve can cut off or fail to stabilise the flow, causing the flame to extinguish during operation. Check modulation/control voltage during operation and the adjustment/offset and pressure at the gas test point. |
| F.61 | Gas valve activation error | The coil/actuator of THIS valve is open/short-circuited or not receiving the command from the PCB, preventing its opening/closing. Check coil continuity/ohmage, command voltage, and harness/connector to the valve assembly. |
| F.62 | Gas valve disconnection delay | Delayed closure or internal leak in THIS valve causes the flame signal to persist after the shutdown command. Check the tightness of the assembly and ensure that the pressure at the burner connection drops to zero when the demand is cut (and immediate cessation of ionisation). |