Vaillant Turboblock Gas Valve VCM ES 182 1 Ref. 053473

Vaillant Turboblock Gas Valve VCM ES 182 1 Ref. 053473

65 €VAT includedIn stock · 5 units

Gas valve: reconditioned spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with VCM 180/1, VCM 182/1 E, VCM 240/1 (ref. 053473). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
053473
Brand
Vaillant
Type of part
Gas valves
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 053473) equips these models. Verified compatibility; check the reference before purchasing.

Turboblock VCM

  • VCM 180/1
  • VCM 182/1 E
  • VCM 240/1
  • VCM 242/1 E
  • VCM 260/1
  • VCM 282/1 E

VC (atmospheric block)

  • VC 240/1
  • VC 242/1 E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.61Fuel valve activation errorThe gas valve cannot be actuated (coils in short circuit or without power supply) and the electronics detect a control fault; check voltage/ground at the connector, continuity of coils and wiring harness.
F.62Fuel valve disconnection delay errorThe gas valve closes with a delay or presents a leak, so the flame signal persists after the shutdown command; check the valve's tightness and ensure that ionisation drops immediately when the demand is cut.
F.27Safety shutdown: Flame simulationWith the valve closed, a flame signal is detected; an internal leak of the valve (solenoid not closing) causes false ionisation; check for valve leaks with a tightness test and rule out moisture/electronics.
F.28Start-up fault: ignition failedA faulty gas valve may not open or may not provide the minimum flow at startup, causing ignition failure; check the power supply to the valve during ignition and pressure/flow in the gas ramp.
How do I know if this gas valve is the one for my boiler?
Verify the reference 053473 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Honeywell piece.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.