Vaillant Turbotec Gas Valve VMW ES 242 4 5 MR1 Honeywell Ref. 0020019992

Vaillant Turbotec Gas Valve VMW ES 242 4 5 MR1 Honeywell Ref. 0020019992

40 €VAT included

Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with VM 242/4-5 (VM24245), VMW ES 242/4-5, VM 240/3-5 (M24035) (ref. 0020019992). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
0020019992
Brand
Vaillant
Type of part
Gas valves
Available units
0 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 0020019992) equips these models. Verified compatibility; check the reference before purchasing.

Vaillant Turbotec / VM-VMW ES (LPG butane-propane)

  • VM 242/4-5 (VM24245)
  • VMW ES 242/4-5
  • VM 240/3-5 (M24035)
  • VMW 255/4-7 (VMW25547)

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.61Fault: gas valve operationThe PCB cannot actuate the gas valve (coils short-circuited/open or harness damaged), so it does not open/close. Check continuity/insulation of coils and wiring to the valve and ensure the PCB delivers a signal according to the manual.
F.62Gas valve disconnection delayThe gas valve does not close in time or remains slightly open, and the equipment detects gas/flame after the stop command. Check the valve's tightness and closure (leak test and ionization reading) and the electrical condition of the valve/wiring.
F.26Stepper motor current of gas valve not plausibleStepper motor fault of the gas valve (disconnected, faulty, or with interrupted wiring) prevents positioning. Check connectors/harness, coil resistance of the stepper, and signal from the PCB; replace the valve if the motor does not respond.
F.27Safety shutdown: flame simulationAn internal leak in the gas valve (solenoid that does not close tightly) can allow gas to pass through and the equipment 'sees' a flame without demand. Check the tightness and closure of the solenoid with a leak test/manometer and electrical check of the valve.
F.28The appliance does not start: unsuccessful ignition attemptsIf the gas valve is faulty, improperly adjusted, or not the correct part, it does not supply gas for ignition. Check inlet pressure, valve adjustment/offset, and control from the PCB; confirm with diagnostics that the valve operates and replace/adjust if necessary.
How do I know if this gas valve is the one for my boiler?
Verify the reference 0020019992 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Honeywell piece.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.