Baxi Roca Victoria 24 24 F PCB Ref. 125568739

Baxi Roca Victoria 24 24 F PCB Ref. 125568739

80 €VAT included

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Compatible with Victoria 20/20, Victoria 24/24, Victoria 24/24 F (ref. 125568739). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
125568739
Brand
Baxi Roca
Type of part
PCBs (control boards)
Available units
0 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 125568739) equips these models. Verified compatibility; check the reference before purchasing.

Victoria

  • Victoria 20/20
  • Victoria 24/24
  • Victoria 24/24 F

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
E99Communication fault between micros or PCB errorThe PCB fails in its self-diagnosis/internal communication (between microcontrollers) or with managed elements; check polarity, grounding, and voltages, and if the issue persists, confirm communication lines or test with a known PCB.
E98Communication fault between micros or PCB errorThe PCB shows an internal communication fault (parameters/EEPROM/firmware) that blocks the electronics; check power supply, grounding, and parameter settings after changing the PCB (e.g. F03/F12) and, if not corrected, replace or reprogram the PCB.
E35Parasite flame (flame error)The flame detection stage in the PCB interprets spurious signals due to leaks/currents or a fault in the ionisation circuit; check the ionisation electrode and ground, moisture on the board, and if it persists, measure the signal and test/replace the PCB.
How do I know if this PCB is for my boiler?
Verify the reference 125568739 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Honeywell piece.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.