Bertelli & Partners PCB DBM03A - Ferroli Divatop Low NOx F32
Control PCB manufactured by Bertelli & Partners (B&P), identified on the label with the code DBM03A. It is installed in Ferroli boilers from the Divatop, Divatop Low NOx, and Divatop Micro ranges, in F24 and F32 versions. It is replaced when the original electronic control of the boiler fails and the entire board needs to be replaced.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference I39828411
PCB with reference I39828411. Nine verified compatibilities: Divatop F37 and Divatop Low Nox F24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli Divatop F37 | Divatop | Contrasted |
| Ferroli Divatop Low NOx F24 | Divatop | Contrasted |
| Ferroli Divatop Low NOx F32 | Divatop | Contrasted |
| Ferroli Divatop Micro F32 | Divatop | Contrasted |
| Ferroli Divatop 60 F24 | Divatop | Contrasted |
| Ferroli Divatop 60 F32 | Divatop | Contrasted |
| Ferroli Ferdigit PW F32 | Ferdigit | Contrasted |
| Ferroli Ferdigit Micro F24 | Ferdigit | Contrasted |
| Ferroli Ferdigit F24 | Ferdigit | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. I39828411 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference I39828411. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB I39828411 resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is completely dead: the display doesn't turn on, nothing starts
Cause: The PCB powers the rest of the electronics of the unit. If its input stage fails, no current reaches any component.
Before replacing it, check the fuse on the PCB and that there is mains voltage reaching the input connector.
- 02
You change the setting on the control and the boiler does not respond, it operates on its own.
Cause: The control communicates with the boiler through the PCB. A fault in that bus port interrupts that communication.
Try to operate the boiler using its own buttons: if it responds there but not to the remote control, check the remote control or its wiring first.
- 03
The heating water or tap water fluctuates between very hot and lukewarm for no reason.
Cause: The PCB regulates the flame modulation. If that function fails, the boiler does not dose the power correctly.
First, rule out scale in the heat exchanger or a dirty temperature sensor, as they produce the same effect.
- 04
The boiler requests heat, but neither the pump nor the fan starts; everything remains still.
Cause: The start command for these components comes from the PCB. If that output is damaged, it won't reach them even if the rest is functioning properly.
Manually check that the pump spins freely before replacing the PCB: if it is stuck after the summer, the fault is with the pump.
Fault codes for Ferroli that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| A09 | Gas valve anomaly | A problem has been detected in the gas valve. This may cause the boiler to not function properly. Check the condition of the valve and its connection. |
| A16 | Gas valve anomaly | A problem has been detected in the gas valve. This may cause the boiler to not function properly. Check the condition of the valve and its connection. |
| F50 | Internal error of the control board | An internal error has occurred in the DBM32 control board. This may affect the operation of the boiler. It is advisable to contact a specialized technician. |
| F51 | Internal error of the control board | An internal error has occurred in the DBM32 control board. This may affect the operation of the boiler. It is advisable to contact a specialized technician. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ferroli PCB I39828411
- Catalogue reference
- I39828411
- Brand
- Ferroli
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- Bertelli & Partners (B&P)
- Component code (silkscreen)
- DBM03A
- The actual manufacturer of the PCB is Bertelli & Partners (B&P), not Ferroli; Ferroli is the brand of the boiler, not of the PCB.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli Divatop Low NOx F24 Manual (PDF)Document © Ferroli, provided as a technical reference.