Hermann Micra 23 SE PCB (control board)

Hermann Micra 23 SE PCB (control board)

Stock · 3 units

The control PCB of the Hermann Micra 23 SE manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, lock out, or behave erratically. This model is compatible with the Renova Micra range, including the Renova Micra 23 SE model, among others. It is replaced when these symptoms occur or if a malfunction in the boiler control is detected.

VAT included

Compatibility

Renova boilers compatible with reference 052002484

PCB with reference 052002484. A proven compatibility: Renova Micra 23 SE.

Proven compatibility

Boiler modelFamilyVerification
Renova Renova Micra 23 SERenova MicraContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 052002484 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 052002484. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 052002484 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is completely off, with no indicator lights or display.

    Cause: The PCB is not receiving or distributing power to the rest of the control circuit.

    Check that there is voltage at the boiler's power supply and that the main switch is in the correct position before replacing the PCB.

  • 02

    A fault code appears and reappears immediately after resetting.

    Cause: The PCB shuts down the operation because a safety signal is outside the expected values.

    Identify the code and check the associated component (flame, pressure, sensor) before blaming the PCB.

  • 03

    Clicking sounds from a relay on the PCB can be heard even though the boiler does not start.

    Cause: A relay with poor contact, like the one marked on the label of this PCB, tries to switch without succeeding.

    Listen to see if the clicking coincides with the moment of the heat demand; if so, the relay on the PCB is suspect.

  • 04

    The electronic control does not respond to any button on the panel.

    Cause: The microcontroller on the PCB has locked up and stops processing commands.

    Cut the power for a few seconds to force a complete reset before replacing the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the PCB Renova 052002484

Catalogue reference
052002484
Brand
Renova
Type of part
PCBs (control boards)
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Partial relay code
6270
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 052002484

Is it an original Hermann PCB for the Micra 23 SE?
Yes, the label has the Hermann logo printed directly on the piece.
For which models is the Hermann Micra 23 SE PCB compatible?
It is only compatible with the Renova Micra 23 SE model.
When should I change the Hermann Micra 23 SE PCB?
When the boiler's electronic control fails.
What is the reference for the PCB for the Micra 23 SE?
The reference is PLRM23SE.
Are there documented fault codes for this PCB?
No, there are no documented fault codes for this product.

Spare parts related to Renova Renova Micra

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Hermann Micra 23 SE PCB (control board)