Honeywell Module R221A For Hermann Micra 2 30 SE Boiler - Cd. 052.004.901

Honeywell Module R221A For Hermann Micra 2 30 SE Boiler - Cd. 052.004.901

Stock · 1 unit

Electronic module with Honeywell logo printed, type Sw R221A and Honeywell code (Cd.) 052.004.901 marked on the label. It is installed as a spare part in Hermann boilers of the Micra 2, Habitat 2, and Micra Condensing series, although the actual manufacturer of the component is Honeywell and not Hermann.

VAT included

Compatibility

Renova boilers compatible with reference H052004901

PCB with reference H052004901. Four confirmed compatibilities: Habitat 2 (family confirmed with >=3 sources); codes 23 E / 24 SE only 2 sources and Micra 2 (family confirmed with >=3 sources); codes 23 E / 24 SE / 30 SE only 2 sources.

Proven compatibility

Boiler modelFamilyVerification
Renova Habitat 2 (family confirmed from >=3 sources); codes 23 E / 24 SE only 2 sources.Hermann Habitat 2Contrasted
Renova Micra 2 (family confirmed by >=3 sources); codes 23 E / 24 SE / 30 SE only 2 sources.Hermann Micra 2Contrasted
Renova Atlas (family confirmed by >=3 sources); codes 24 C / 24 F / 30 F only 2 sources.Tiberis AtlasContrasted
Renova Oberon (family confirmed by >=3 sources); codes 18 F / 24 C / 24 F / 28 F only 2 sources.Tiberis OberonContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. H052004901 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference H052004901. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB H052004901 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    When pressing the reset button, the boiler starts for a moment and then quickly locks out again.

    Cause: The PCB does not maintain a stable flame or ignition signal, which repeatedly activates the safety lockout.

    Note the lock code displayed before resetting, to determine if it indicates flame, fan, or lack of water.

  • 02

    The screen remains blank or flickers without displaying temperature or fault code.

    Cause: The circuit that powers the display is part of the PCB, and if it fails, it does not show information even though the boiler receives power.

    Check that the flat cable or display connector is properly inserted before considering that the PCB is faulty.

  • 03

    The circulation pump does not start even though the boiler requests heating.

    Cause: The PCB commands the pump to start, and a fault in its power output prevents the order from being executed.

    Check if the pump rotates manually after loosening the front screw before discarding the PCB.

  • 04

    The boiler turns off by itself a few minutes after starting to operate in heating mode.

    Cause: A fault in the control electronics can interrupt the cycle, even if the other components are in good condition.

    Check that there is no fault code for temperature or pressure before attributing it to the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Renova H052004901 PCB.

Catalogue reference
H052004901
Brand
Renova
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Honeywell code (Cd.)
052.004.901
Type/model (Sw)
R221A
Low number Sw R221A
070641
Manufacturing date (Date)
0307
Before purchasing
  • The actual manufacturer of this module is Honeywell; the logo is printed on the piece itself, although it is sold as a spare part for Hermann boilers.
Frequently Asked Questions

Frequently asked questions about the PCB H052004901

Is the Honeywell R221A Cd. 052.004.901 module compatible with the Hermann Habitat 2 28 SE?
Yes, the Habitat 2 28 SE is on the list of boilers compatible with this module.
Who manufactures the Honeywell R221A module for my Micra 2 30 SE boiler?
The manufacturer is Honeywell; the Honeywell logo is printed on the module.
What should I look for on the label to confirm that I have the correct module for my boiler?
You need to look for Sw R221A and Cd. 052.004.901 on the module label.
Is this module also compatible with the Hermann Micra 2 23 E?
Yes, the Micra 2 23 E is one of the models compatible with this module.
How many models are compatible with the Honeywell R221A module?
There are a total of 4 confirmed models compatible with this module.
What is the reference for the Honeywell module for the Hermann Micra 2 30 SE boiler?
The reference is DCM230SE.

Spare parts related to Renova Hermann Habitat 2

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell Module R221A For Hermann Micra 2 30 SE Boiler - Cd. 052.004.901