Hermann Micraplus 24 Membrane Display/Keyboard - Ref. 0020141440
The Hermann Micraplus 24 membrane keyboard/display, with reference 0020141440, is a control PCB that manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or operate erratically. This part is compatible with models from the Micraplus range, such as the 24, 24 SE-A/1, and NOX 24-B/2, among others. It is recommended to replace it if you experience ignition issues or general operational problems with the boiler.
VAT included
Consult via WhatsAppCompatible Hermann boilers
PCB. Three confirmed compatibilities: 24 and 24 SE-A/1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Hermann 24 | MICRAPLUS | Contrasted |
| Hermann 24 SE-A/1 | MICRAPLUS | Contrasted |
| Hermann NOx 24-B/2 | MICRAPLUS | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB (control board) resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The membrane buttons do not respond to touch, even when pressed firmly.
Cause: Membrane keyboards lose internal contact with use and humidity, and stop transmitting the keystroke even though they may appear normal on the outside.
Press each button more firmly and at different points on the touch area; if any respond intermittently, it is more likely a membrane wear issue than a total electrical failure.
- 02
The screen does not turn on, although the boiler continues to heat normally.
Cause: This module is the visible part of the panel; if it fails, the information is lost but not necessarily the internal functioning of the boiler.
Check if the boiler is still providing heating or hot water despite the panel being off; this helps to isolate the fault in this part.
- 03
The temperature cannot be seen or adjusted from the panel.
Cause: Without a functional screen or keyboard, manual control is lost, even though the main electronics continue to operate.
If there is a programmable thermostat or another external control, check if the boiler can still be adjusted from there; this confirms that the fault is in this panel.
- 04
Some buttons on the membrane respond while others do not, in an irregular manner.
Cause: It is common in worn membrane keyboards, where the deterioration does not affect all buttons equally.
Note which specific buttons are failing and which are not; if it is a partial pattern, it is advisable to check for moisture or dirt in that area before replacing the entire part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Hermann PCB data sheet
- Brand
- Hermann
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Type of component
- Membrane screen / keyboard of the control panel
- Partial marking on label
- "C€ 1508", next to a small component; probably CE mark + week/year code, not a part code.
- The marking "C€ 1508" visible next to a component is partial and does not function as a part code; it is likely a CE marking with week/year code. It is not useful for ordering the part by reference.