The Hermann Micraplus 24 membrane keyboard/display, with reference 0020141440, is a control PCB that manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or operate erratically. This part is compatible with models from the Micraplus range, such as the 24, 24 SE-A/1, and NOX 24-B/2, among others. It is recommended to replace it if you experience ignition issues or general operational problems with the boiler.

VAT included

Compatibility

Compatible Hermann boilers

PCB. Three confirmed compatibilities: 24 and 24 SE-A/1.

Proven compatibility

Boiler modelFamilyVerification
Hermann 24MICRAPLUSContrasted
Hermann 24 SE-A/1MICRAPLUSContrasted
Hermann NOx 24-B/2MICRAPLUSContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB (control board) resolves

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The membrane buttons do not respond to touch, even when pressed firmly.

    Cause: Membrane keyboards lose internal contact with use and humidity, and stop transmitting the keystroke even though they may appear normal on the outside.

    Press each button more firmly and at different points on the touch area; if any respond intermittently, it is more likely a membrane wear issue than a total electrical failure.

  • 02

    The screen does not turn on, although the boiler continues to heat normally.

    Cause: This module is the visible part of the panel; if it fails, the information is lost but not necessarily the internal functioning of the boiler.

    Check if the boiler is still providing heating or hot water despite the panel being off; this helps to isolate the fault in this part.

  • 03

    The temperature cannot be seen or adjusted from the panel.

    Cause: Without a functional screen or keyboard, manual control is lost, even though the main electronics continue to operate.

    If there is a programmable thermostat or another external control, check if the boiler can still be adjusted from there; this confirms that the fault is in this panel.

  • 04

    Some buttons on the membrane respond while others do not, in an irregular manner.

    Cause: It is common in worn membrane keyboards, where the deterioration does not affect all buttons equally.

    Note which specific buttons are failing and which are not; if it is a partial pattern, it is advisable to check for moisture or dirt in that area before replacing the entire part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Hermann PCB data sheet

Brand
Hermann
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type of component
Membrane screen / keyboard of the control panel
Partial marking on label
"C€ 1508", next to a small component; probably CE mark + week/year code, not a part code.
Before purchasing
  • The marking "C€ 1508" visible next to a component is partial and does not function as a part code; it is likely a CE marking with week/year code. It is not useful for ordering the part by reference.
Frequently Asked Questions

Frequently asked questions about the PCB (control board)

Is the Ref. 0020141440 suitable for the boiler Hermann Micraplus 24 SE-A/1?
Yes, it is one of the three confirmed models, along with Micraplus 24 and Micraplus NOX 24-B/2.
What fault requires the replacement of the membrane screen of the Micraplus NOX 24-B/2?
It is replaced when the screen does not turn on or the buttons do not respond.