Hermann Micra 2 Honeywell PCB
The Honeywell Hermann Micra 2 PCB is the component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or operate erratically. This board is compatible with models from the Hermann Micra 2 range, as well as some models from the Hermann Habitat 2 range, among others. It is recommended to replace the PCB when these symptoms occur to restore the normal operation of the boiler.
VAT included
Consult via WhatsAppHermann boilers compatible with reference 0020038693
PCB with reference 0020038693. Six confirmed compatibilities: Habitat 2 23 E and Habitat 2 24 SE.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Hermann Habitat 2 23 E | Hermann Habitat 2 | Contrasted |
| Hermann Habitat 2 24 SE | Hermann Habitat 2 | Contrasted |
| Hermann Habitat 2 28 SE | Hermann Habitat 2 | Contrasted |
| Hermann Micra 2 23 E | Hermann Micra 2 | Contrasted |
| Hermann Micra 2 24 SE | Hermann Micra 2 | Contrasted |
| Hermann Micra 2 30 SE | Hermann Micra 2 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 0020038693 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0020038693. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 0020038693 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on: there are no lights, no display, and no sound.
Cause: The PCB is not sending current to the other components.
Check the fuse and the power supply before considering that the PCB is faulty.
- 02
The boiler tries to ignite and shuts down quickly, repeating the process.
Cause: The PCB interrupts the ignition because it receives an incorrect signal from a sensor.
Check the pressure switch, the temperature sensor, and its wiring before blaming the PCB.
- 03
The remote control does not respond to the presses, as if the boiler does not recognize it.
Cause: A fault in the microprocessor of the PCB prevents processing the user's commands.
Turn off the main power for a couple of minutes and then turn it back on to rule out a temporary fault.
- 04
An error code appears on the display that does not clear when resetting.
Cause: The PCB keeps the safety lock while detecting the same anomaly.
Note the code and check the component indicated first before replacing the PCB.
Fault codes Hermann that this part solves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.27 | The boiler turns off and does not ignite. | The boiler has shut down due to a flame detection error. This may be due to moisture in the electronics of the PCB or a fault in the gas valve, which may be related to the PCB. |
| F.29 | The boiler loses the flame during operation. | A flame loss has been detected. This may be due to an interruption in the gas supply or a fault in the PCB that prevents the correct detection of the flame. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the PCB Hermann 0020038693
- Catalogue reference
- 0020038693
- Brand
- Hermann
- Type of part
- PCBs (control boards)
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Honeywell