Main Control PCB Vaillant Ecotec Plus VMW ES 236 3 5 Ref. 0020132764

Main Control PCB Vaillant Ecotec Plus VMW ES 236 3 5 Ref. 0020132764

Stock · 7 units

Main Control PCB Vaillant Ecotec Plus VMW ES 236 3 5 Ref. 0020132764. This control PCB manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, lock out, or behave erratically, displaying fault codes such as F.61, F.62, F.63, F.64, or F.65. It is compatible with boilers from the ecoTEC pro range, such as the model VMW 226/3-3 and VMW 236/3-5, among others. It should be replaced when it shows operational faults or system errors.

VAT included

Compatibility

Vaillant boilers compatible with reference 0020132764

PCB with reference 0020132764. Two confirmed compatibilities: VMW 226/3-3 and VMW 236/3-5.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 226/3-3ecoTEC proContrasted
Vaillant VMW 236/3-5ecoTEC proContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020132764 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020132764. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 0020132764 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is completely off, with no display or indicators, even though there is power in the house.

    Cause: The PCB controls the power supply to the entire boiler; if it fails, no current reaches the other components.

    Check the main fuse of the installation and the one for the PCB before considering the PCB as lost.

  • 02

    A different fault code appears each time, or the same error comes and goes without a pattern.

    Cause: The sensor and pressure switch reading circuits on the PCB are intermittently failing and generating errors that do not correspond to a real fault.

    Note the codes that appear and compare them with the manual: if they indicate different parts each time, suspect the PCB.

  • 03

    The boiler does not respond to the thermostat or the remote control, although they seem to be working.

    Cause: The communication module integrated into the PCB stops understanding the commands it receives.

    First, check that the wiring or the connection of the thermostat to the boiler is properly done.

  • 04

    Every time the fuse is replaced, it blows again shortly after turning on the boiler.

    Cause: A damaged component within the PCB causes a short circuit that repeatedly blows the fuse.

    Do not replace the fuse more than once: if it blows again, it is a clear sign of an internal fault in the PCB.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.61Fuel valve control faultThe PCB (0020132764) may fail at the control stage to the gas valve, so it does not send the correct signal/voltage and the valve assembly does not activate; check the voltage/signal from the connector on the PCB to the valve and the continuity of the harness.
F.62Fuel valve disconnection delay faultThe PCB electronics may unduly delay the closure of the gas valve (shutdown circuit), generating the fault; check that the PCB output/relay cuts off immediately upon flame loss and rule out a mechanical leak in the valve.
F.63EEPROM faultCorruption or defect of the EEPROM integrated in the PCB; if after resets the code persists, confirm with diagnosis and replace/parameterize the PCB according to the manufacturer's procedure.
F.64Electronic fault/sensorFault in the analog/ADC circuit of the PCB that measures the NTC (flow/return); first check the NTC and wiring, and if they are correct, confirm a defect in the PCB electronics.
F.65Electronic temp. faultOverheating/thermal damage in the PCB electronics; inspect the location and external heat sources and check the PCB (signs of heat, degraded components) and its ventilation.
F.67Electronic/flame faultFault in the flame detection circuit/ASIC of the PCB causing an implausible flame signal; check the grounding, ionisation electrode/cable, and if the signal is correct, the PCB electronics.
F.70Fault: invalid appliance codeAfter replacing the PCB, the DSN/appliance code does not match or the coding resistor is missing; verify and configure the DSN in d.93 or install the correct coding resistor for the new PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant PCB 0020132764.

Catalogue reference
0020132764
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

voltage
12 V
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 0020132764

Does this PCB work for a Vaillant VMW 236/3-5 boiler?
Yes, it is on the list of compatible boilers, along with the model VMW 226/3-3.
What are the compatible models with the Vaillant Ecotec Plus VMW ES 236 3 5 Main Control PCB Ref. 0020132764?
The compatible models are VMW 226/3-3 and VMW 236/3-5.
When should this PCB from the ecoTEC pro series be replaced?
When the original PCB of the boiler fails, check that the exact model of yours is on the list of compatible ones.
What fault codes are documented for this PCB?
The documented fault codes are: F.61, F.62, F.63, F.64, F.65, F.67, F.70.
What is the reference for the Vaillant Main Control PCB?
The reference is PEPVMW236.

Spare parts related to Vaillant ecoTEC pro

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model