Vaillant PCB VMW 226/3-3 Ref. 0020132764

Vaillant PCB VMW 226/3-3 Ref. 0020132764

Stock · 1 unit

Control PCB for Vaillant boilers VMW 226/3-3 and related models from the VM/VMW 3-3 and 3-5 range, with reference 0020132764. The circuit is printed with "Vaillant-Group," text that identifies the design of the board, not an external manufacturer of the component. It manages ignition, safety, and communication with the controls. It is replaced when the boiler does not ignite or the board stops responding.

VAT included

Compatibility

Vaillant boilers compatible with reference 0020132764

PCB with reference 0020132764. Two confirmed compatibilities: VMW 226/3-3 and VMW 236/3-5.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 226/3-3ecoTEC proContrasted
Vaillant VMW 236/3-5ecoTEC proContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020132764 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020132764. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 0020132764 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler turns off by itself during operation and needs to be reset to start again.

    Cause: An intermittent fault in the control board can cut off power to the safety components and force a lockout.

    Check that it is not an intermittent power supply cut (power strip, socket) before replacing the PCB.

  • 02

    The display shows a specific fault related to electronics or the PCB, and it does not disappear after resetting.

    Cause: The control board performs self-diagnosis and locks the boiler when it detects an internal fault that it cannot resolve.

    Reset the boiler by cutting off the power for one minute; if the fault code reappears immediately, the PCB is likely faulty.

  • 03

    The connection with the room thermostat is lost and the boiler does not heat even though it is cold in the house.

    Cause: If the communication module of the PCB fails, it does not receive the heating request from the thermostat.

    Try bypassing the demand directly at the boiler, according to the manual, to see if it starts without the thermostat in between.

  • 04

    The boiler does not ignite in any mode, neither heating nor domestic hot water.

    Cause: A general fault in the PCB leaves both circuits of the boiler unmanaged at the same time.

    Check that the mode selector of the boiler is not in the off or summer position before replacing the PCB.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.61Fuel valve control faultThe PCB (0020132764) may fail at the control stage to the gas valve, so it does not send the correct signal/voltage and the valve assembly does not activate; check the voltage/signal from the connector on the PCB to the valve and the continuity of the harness.
F.62Fuel valve disconnection delay faultThe PCB electronics may unduly delay the closure of the gas valve (shutdown circuit), generating the fault; check that the PCB output/relay cuts off immediately upon flame loss and rule out a mechanical leak in the valve.
F.63EEPROM faultCorruption or defect of the EEPROM integrated in the PCB; if after resets the code persists, confirm with diagnosis and replace/parameterize the PCB according to the manufacturer's procedure.
F.64Electronic fault/sensorFault in the analog/ADC circuit of the PCB that measures the NTC (flow/return); first check the NTC and wiring, and if they are correct, confirm a defect in the PCB electronics.
F.65Electronic temp. faultOverheating/thermal damage in the PCB electronics; inspect the location and external heat sources and check the PCB (signs of heat, degraded components) and its ventilation.
F.67Electronic/flame faultFault in the flame detection circuit/ASIC of the PCB causing an implausible flame signal; check the grounding, ionisation electrode/cable, and if the signal is correct, the PCB electronics.
F.70Fault: invalid appliance codeAfter replacing the PCB, the DSN/appliance code does not match or the coding resistor is missing; verify and configure the DSN in d.93 or install the correct coding resistor for the new PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant PCB 0020132764.

Catalogue reference
0020132764
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Silkscreen on the PCB
Vaillant-Group | TL-AL | connection strip: - + 7 8 9 I L N (ground) 3 4 5
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 0020132764

Is the Hongfa relay I see mounted the manufacturer of this PCB for the VM 246/3-5?
No, Hongfa is the manufacturer of the relay mounted on the PCB, not of the complete board.
Is this PCB Ref. 0020132764 compatible with my Vaillant VMW 226/3-3?
Yes, that model is on the list of compatible boilers for this PCB.
What is this PCB used for in a Vaillant VM 356/3-5 R3?
It manages the ignition, safety, and communication with the controls of the boiler; it is replaced when the boiler does not ignite or the PCB stops responding.

Spare parts related to Vaillant ecoTEC pro

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Vaillant PCB VMW 226/3-3 Ref. 0020132764