Vaillant VMW 282/2-5 R1 Control PCB Ref. TL-AD/68

Vaillant VMW 282/2-5 R1 Control PCB Ref. TL-AD/68

Control PCB for Vaillant boilers (logo printed on the PCB) for Turbomax Plus models from the VMW, VM, VU, VUI, and VUW series indicated. The terminal block is labeled with 230V mains and 21V auxiliary, with a T3.15A fuse. On the edge, it has the code TL-AD/68. Replacement requires first confirming the fault of the part through technical diagnosis, even when the PCB loses control or ignition voltage.

Catalogue reference
0020034604
Warranty
1 year
VAT included Stock · 9 units
Compatibility

Vaillant boilers compatible with reference 0020034604

PCB with reference 0020034604. 14 verified compatibilities: VMW 240/2-3 and VMW 240/2-3 R1.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 240/2-3VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 240/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R2VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 280/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 282/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VM 240/2-5VM (heating only)Contrasted
Vaillant VM 242/2-5VM (heating only)Contrasted
Vaillant VM 280/2-5VM (heating only)Contrasted
Vaillant VM 282/2-5VM (heating only)Contrasted
Vaillant VM 202/2-5VM (heating only)Contrasted
Vaillant VMI 280-7VMI (compact interior)Contrasted
Vaillant VMI 282-7VMI (compact interior)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020034604 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020034604. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 0020034604

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shows no signs of life: no display, no fan, no noise when turning it on.

    Cause: If 230 V from the mains does not reach the PCB, there is no power for any circuit of the boiler to operate.

    Before discarding the PCB, check with a multimeter that 230 V is reaching the input connector of the board.

  • 02

    The display lights up, but the boiler does not respond when you request heating.

    Cause: The T3.15A fuse may be blown, cutting off the 21 V that powers the internal control circuit.

    Check the T3.15A fuse or measure it with a multimeter; if it is blown, verify what caused it to burn out (pump, gas valve) before replacing it.

  • 03

    The remote control or the thermostat do not communicate with the boiler, or indicate a communication error.

    Cause: The relay or the transformer on the PCB that manages communication with the control may be damaged.

    Before changing the PCB, check that the communication bus cable to the control is properly connected and free of oxidation.

  • 04

    The boiler turns off by itself a few seconds after trying to ignite, as if something is stopping it.

    Cause: If the control circuit fails, the control unit may incorrectly interpret a safety signal and block the ignition.

    Before blaming the PCB, rule out faults in the pressure switch, the NTC sensor, or the ionization electrode, which can cause the same problem.

Vaillant fault codes that require diagnosis

CodeFaultTechnical checks
F.63Error in the boiler configuration memoryThe EEPROM memory is on this main PCB. If the memory fails or gets corrupted, the board is to blame. Check: if the error persists after a reset and everything is properly connected, it's time to replace the board.
F.64Fault in the electronics or short circuit in NTC sensorsIf the NTC sensors and their wiring are fine and there is no short circuit, the problem lies in the electronics that process the signals. Check: if the sensors and connections are correct but the fault persists after resetting, the PCB is defective.
F.65The PCB overheats.The temperature sensor on the PCB detects too much heat. If there is no external heat source or poor ventilation, the board has a defect. Check: if the environment and ventilation are normal but the fault persists, the board is faulty.
F.61The electronics do not control the gas valve properly.The PCB is the one that controls the gas valve. If the wiring and the valve are fine, the problem may be the PCB. Check: if the wiring and the coils of the valve are correct but the fault persists, the PCB may be the cause (although it is not the only possible one).
F.62The gas valve takes time to turn off.The PCB controls the closure of the gas valve and the signal from the electrode. If the valve and the electrode are fine, the problem may be with the control electronics. Check: if the valve and the electrode are correct but the fault persists, the PCB may be the cause (along with the valve or the electrode).

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 0020034604 PCB.

Catalogue reference
0020034604
Uniclima internal SKU
PETPVMW282R1
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
9 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Mains voltage
230V
Auxiliary voltage
21V
Assembly group code (Baugruppe)
712024/25/28, 712026/27/29/30/31
Relay/transformer code
E 30-305TC/48/S12
Fuse
T3.15A
PCB code (edge, next to "Vaillant 2001")
TL-AD/68
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 0020034604

Is this PCB with code TL-AD/68 an original Vaillant PCB for the VMW 282/2-5 R1?
Yes, the Vaillant logo is printed directly on the PCB.
What fuse does the PCB of the VU 282/2-5 R1 use?
A T3.15A fuse.
Is this PCB suitable for the Vaillant VUI 362-7?
Yes, it is on the list of compatible boilers along with VM 282/2-5 R1, VMW 242/2-5 R1, VMW 282-5, VMW 282/2-5 R1, and VU 282/2-5 R1.
What voltages does the terminal block of this PCB handle in the VMW 242/2-5 R1?
230V mains and 21V auxiliary.
When should this PCB be replaced in a VMW 282/2-5 R1?
The technical diagnosis must confirm that it is necessary to replace it, even when the PCB loses control or ignition voltage.

Spare parts related to Vaillant VMW (combi turboTEC/turboMAX, wall-mounted combi)

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Vaillant VMW 282/2-5 R1 Control PCB Ref. TL-AD/68