PCB for Vaillant boilers VMW, VU, VUW, and Aquaplus VUI, reference 0020034604. This control PCB is responsible for managing the ignition, burner modulation, pump, and safety features of the boiler. When it malfunctions, the boiler may fail to start, lock out, or operate erratically. It is compatible with models such as VMW 240/2-3, VM 240/2-5, and VMI 280-7, among others. It is recommended to replace it upon detecting any of the faults F.61, F.62, F.63, F.64, or F.65.

VAT included

Compatibility

Vaillant boilers compatible with reference 0020034604

PCB with reference 0020034604. 14 verified compatibilities: VMW 240/2-3 and VMW 240/2-3 R1.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 240/2-3VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 240/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R2VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 280/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 282/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VM 240/2-5VM (heating only)Contrasted
Vaillant VM 242/2-5VM (heating only)Contrasted
Vaillant VM 280/2-5VM (heating only)Contrasted
Vaillant VM 282/2-5VM (heating only)Contrasted
Vaillant VM 202/2-5VM (heating only)Contrasted
Vaillant VMI 280-7VMI (compact interior)Contrasted
Vaillant VMI 282-7VMI (compact interior)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020034604 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020034604. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 0020034604 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not respond when pressing the control.

    Cause: If the 1.25A fuse has blown, the PCB loses all power.

    Check the 1.25A fuse with the multimeter before ordering the PCB.

  • 02

    No indicator lights or display turn on, even though the boiler has power.

    Cause: If the fuse of the secondary transformer has blown, there is no power supply to the control part.

    Check the condition of the fuse visually before replacing the complete PCB.

  • 03

    The display shows a control board or PCB error.

    Cause: The circuit locks the unit when it detects an internal anomaly.

    Note the code and try to reset the boiler; if the fault returns, rule out that it was something temporary.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.63EEPROM error: fault in the configuration memory of the boiler's electronics.The EEPROM physically resides on this main PCB; if the memory becomes corrupted or fails, the cause is the board itself. Verify: after a reset, the code persists and, with correct connections and sensors, the fault reproduces; confirm replacement of the board.
F.64Electronics error / NTC: fault in the electronics or short circuit in the flow/return NTC sensors.When a short circuit in the NTC is ruled out (by checking sensors and wiring with a multimeter), the fault in the electronics processing those signals points to this main PCB. Verify: NTC and connections are correct but the fault code persists after reset = defective PCB.
F.65Temperature error in the electronics: the PCB is overheating.The temperature sensor of the electronics itself detects excess heat on the PCB; if an external heat source or lack of ventilation is ruled out, the origin is a defect in the PCB. Verify: normal environment/ventilation but the code repeats = faulty PCB.
F.61Fault in the regulation/activation of the gas valve: the electronics cannot control the gas valve.The PCB is the one that controls the gas valve; with wiring to ground, short circuit, and the valve itself ruled out using a multimeter, the remaining documented cause is the PCB. Verify: wiring and valve coils are correct but the code persists = defective PCB (the PCB is one of the causes, not the only one).
F.62Gas valve error due to delayed shutdown: delayed disconnection of the gas valve detected.The PCB manages the closing/timing of the valve and the electrode signal; with the valve and detection electrode ruled out, the control electronics defect points to this PCB. Verify: valve and electrode are correct but the code repeats = PCB (concurrent cause with valve/electrode).

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 0020034604 PCB.

Catalogue reference
0020034604
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Transformer supply voltage
230V 50-60Hz
Secondary transformer voltage
21V
Fuse
T1.25A
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 0020034604

Is this PCB Ref. 0020034604 suitable for the Vaillant Aquaplus VUI 362-7?
Yes, the Aquaplus VUI 362-7 is on the list of boilers compatible with this PCB, along with models VMW, VU, and VUW.
What fuse does this PCB use in the Vaillant VUW 282/2-5?
A 1.25A fuse that protects the 21V secondary circuit.
When should this PCB be replaced in a Vaillant VMW 242-5?
When the boiler does not ignite or shows an electronic fault, the transformer on the PCB reduces the mains voltage to 21V for that circuit.

Spare parts related to Vaillant VMW (combi turboTEC/turboMAX, wall-mounted combi)