Vaillant PCB Control VMW 24 282 5 R2 Ref. 0020034604

Vaillant PCB Control VMW 24 282 5 R2 Ref. 0020034604

Stock · 4 units

The Vaillant VMW 24 282 5 R2 Control PCB is the component that regulates the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may notice that the boiler does not start, gets locked, or exhibits erratic operation. This board is compatible with several models, such as the VMW 240/2-3, VMW 242-5, VM 242/2-5, among others. It is advisable to replace it if errors such as F.63, F.64, F.65, F.61, or F.62 appear.

VAT included

Compatibility

Vaillant boilers compatible with reference 0020034604

PCB with reference 0020034604. 14 verified compatibilities: VMW 240/2-3 and VMW 240/2-3 R1.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 240/2-3VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 240/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R2VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 280/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 282/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VM 240/2-5VM (heating only)Contrasted
Vaillant VM 242/2-5VM (heating only)Contrasted
Vaillant VM 280/2-5VM (heating only)Contrasted
Vaillant VM 282/2-5VM (heating only)Contrasted
Vaillant VM 202/2-5VM (heating only)Contrasted
Vaillant VMI 280-7VMI (compact interior)Contrasted
Vaillant VMI 282-7VMI (compact interior)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020034604 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020034604. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 0020034604 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is locking with a fault code that does not clear after several reset attempts.

    Cause: The PCB remains locked while it detects a fault, even if the real cause is elsewhere.

    Note the code and consult the manual to identify the indicated component; make sure to rule out that external element before replacing the PCB.

  • 02

    The panel does not light up at all, the boiler seems completely off.

    Cause: If the PCB does not receive power, there will be no visible signal, not even a standby one.

    Check that power is reaching the PCB before considering it faulty.

  • 03

    It operates irregularly: some days it starts up fine and other days there is no way to get it to work.

    Cause: An intermittent fault in the control electronics may depend on temperature or vibrations, and it does not always manifest in the same way.

    Note under what conditions it fails (cold, after many hours on, etc.) to have more clues before changing the PCB.

  • 04

    The fan does not start and the boiler does not initiate combustion.

    Cause: The PCB activates the fan through a relay or triac; if that output fails, the fan will not spin even if the rest is functioning.

    Check if the fan spins when powered directly to rule out that the issue is with the fan and not with the PCB.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.63EEPROM error: fault in the configuration memory of the boiler's electronics.The EEPROM physically resides on this main PCB; if the memory becomes corrupted or fails, the cause is the board itself. Verify: after a reset, the code persists and, with correct connections and sensors, the fault reproduces; confirm replacement of the board.
F.64Electronics error / NTC: fault in the electronics or short circuit in the flow/return NTC sensors.When a short circuit in the NTC is ruled out (by checking sensors and wiring with a multimeter), the fault in the electronics processing those signals points to this main PCB. Verify: NTC and connections are correct but the fault code persists after reset = defective PCB.
F.65Temperature error in the electronics: the PCB is overheating.The temperature sensor of the electronics itself detects excess heat on the PCB; if an external heat source or lack of ventilation is ruled out, the origin is a defect in the PCB. Verify: normal environment/ventilation but the code repeats = faulty PCB.
F.61Fault in the regulation/activation of the gas valve: the electronics cannot control the gas valve.The PCB is the one that controls the gas valve; with wiring to ground, short circuit, and the valve itself ruled out using a multimeter, the remaining documented cause is the PCB. Verify: wiring and valve coils are correct but the code persists = defective PCB (the PCB is one of the causes, not the only one).
F.62Gas valve error due to delayed shutdown: delayed disconnection of the gas valve detected.The PCB manages the closing/timing of the valve and the electrode signal; with the valve and detection electrode ruled out, the control electronics defect points to this PCB. Verify: valve and electrode are correct but the code repeats = PCB (concurrent cause with valve/electrode).

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 0020034604 PCB.

Catalogue reference
0020034604
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 0020034604

Is this PCB compatible with the VMW 240/2-3 boiler?
Yes, the VMW 240/2-3 is on the list of models compatible with the Vaillant control PCB VMW 24 282 5 R2, reference PLAVVM28X.
Can I use this PCB in a boiler VM 242/2-5?
Yes, the VM 242/2-5 is one of the models confirmed as compatible.
Does the PCB work for the VMI 282-7 boiler?
Yes, the VMI 282-7 is included in the compatibility table.
What fault codes are compatible with this PCB?
The documented fault codes for this PCB are F.61, F.62, F.63, F.64, and F.65.
How many models are compatible with the Vaillant VMW 24 282 5 R2 control PCB?
A total of 14 models are compatible with this PCB.

Spare parts related to Vaillant VMW (combi turboTEC/turboMAX, wall-mounted combi)

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model