PCB for Vaillant VM, VMI, and VMW Boilers

PCB for Vaillant VM, VMI, and VMW Boilers

Stock · 5 units

If your boiler does not start, locks up, or exhibits erratic behavior, you may need the PCB for Vaillant boilers VM, VMI, and VMW, reference 0020034604. This control board is responsible for managing the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may notice faults such as F.63, F.64, or F.65, which indicate issues with the configuration memory, electronics, or overheating. It is compatible with models such as the VMW 240/2-3, VM 240/2-5, and VMI 280-7, among others. It is recommended to replace it when the mentioned symptoms are detected.

VAT included

Compatibility

Vaillant boilers compatible with reference 0020034604

PCB with reference 0020034604. 14 verified compatibilities: VMW 240/2-3 and VMW 240/2-3 R1.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 240/2-3VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 240/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R2VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 280/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 282/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VM 240/2-5VM (heating only)Contrasted
Vaillant VM 242/2-5VM (heating only)Contrasted
Vaillant VM 280/2-5VM (heating only)Contrasted
Vaillant VM 282/2-5VM (heating only)Contrasted
Vaillant VM 202/2-5VM (heating only)Contrasted
Vaillant VMI 280-7VMI (compact interior)Contrasted
Vaillant VMI 282-7VMI (compact interior)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020034604 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020034604. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 0020034604 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start and does not respond to any controls, as if it were without power.

    Cause: If the secondary fuse blows, the PCB will be left without the 21V it needs to operate.

    Before changing the PCB, measure the 1.25A fuse with the multimeter.

  • 02

    The display does not light up and there are no indicators on.

    Cause: This is usually due to a blown fuse that protects the 21V transformer on the PCB.

    Check the condition of the fuse visually or with a multimeter before replacing it.

  • 03

    A fault code for the PCB or general control appears on the display

    Cause: The control electronics detect an internal fault and lock the unit instead of attempting to ignite it.

    Note the exact code; some can be resolved with a reset and it is not necessary to change anything.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.63EEPROM error: fault in the configuration memory of the boiler's electronics.The EEPROM physically resides on this main PCB; if the memory becomes corrupted or fails, the cause is the board itself. Verify: after a reset, the code persists and, with correct connections and sensors, the fault reproduces; confirm replacement of the board.
F.64Electronics error / NTC: fault in the electronics or short circuit in the flow/return NTC sensors.When a short circuit in the NTC is ruled out (by checking sensors and wiring with a multimeter), the fault in the electronics processing those signals points to this main PCB. Verify: NTC and connections are correct but the fault code persists after reset = defective PCB.
F.65Temperature error in the electronics: the PCB is overheating.The temperature sensor of the electronics itself detects excess heat on the PCB; if an external heat source or lack of ventilation is ruled out, the origin is a defect in the PCB. Verify: normal environment/ventilation but the code repeats = faulty PCB.
F.61Fault in the regulation/activation of the gas valve: the electronics cannot control the gas valve.The PCB is the one that controls the gas valve; with wiring to ground, short circuit, and the valve itself ruled out using a multimeter, the remaining documented cause is the PCB. Verify: wiring and valve coils are correct but the code persists = defective PCB (the PCB is one of the causes, not the only one).
F.62Gas valve error due to delayed shutdown: delayed disconnection of the gas valve detected.The PCB manages the closing/timing of the valve and the electrode signal; with the valve and detection electrode ruled out, the control electronics defect points to this PCB. Verify: valve and electrode are correct but the code repeats = PCB (concurrent cause with valve/electrode).

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 0020034604 PCB.

Catalogue reference
0020034604
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Transformer supply voltage
230V 50-60Hz
Secondary transformer voltage
21V
Fuse
T1.25A
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 0020034604

Is this PCB the same physical part as the one in the PLVMW24R listing for the Vaillant VMW 240/2-3?
Yes, it has the same label and the same screen printing as the PCB from the PLVMW24R datasheet, published for another range of boilers.
Is this PCB Ref. PLCVUW240 suitable for the Vaillant VMI 282-7?
Yes, the VMI 282-7 is on the list of boilers compatible with this PCB, along with other VM, VMI, and VMW models.
What fuse does this PCB use in the Vaillant VMW 240/2-3?
A 1.25A fuse in the secondary circuit at 21V coming from the transformer on the PCB.
When is this PCB replaced in a Vaillant VMW 280/2-5?
When the boiler does not ignite or shows an electronic fault.
How many boiler models are compatible with the PLCVUW240 control board?
A total of 14 models are compatible with this PCB.
What fault codes are compatible with this PCB?
The documented fault codes are F.61, F.62, F.63, F.64, and F.65.

Spare parts related to Vaillant VMW (combi turboTEC/turboMAX, wall-mounted combi)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
PCB for Vaillant VM, VMI, and VMW Boilers