Vaillant Turbomax Plus 824E PCB - Ref. 0020034604

Vaillant Turbomax Plus 824E PCB - Ref. 0020034604

75 €VAT includedOUT OF STOCK

If your boiler does not start, locks out, or exhibits erratic behavior, you may need the Vaillant Turbomax Plus 824E PCB. This part is the brain of the boiler, responsible for controlling the ignition, burner modulation, pump, and safety features. When it fails, it can display faults such as F.63, F.64, F.65, F.61, or F.62. It is compatible with models from the VMW, VM, and VMI ranges, among others. It is replaced when these symptoms or faults in operation occur.

Compatibility

Vaillant boilers compatible with reference 0020034604

PCB with reference 0020034604. 14 verified compatibilities: VMW 240/2-3 and VMW 240/2-3 R1.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 240/2-3VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 240/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R1VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242/2-3 R2VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 242-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 280/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VMW 282/2-5VMW (mixed turboTEC/turboMAX, wall-hung mixed)Contrasted
Vaillant VM 240/2-5VM (heating only)Contrasted
Vaillant VM 242/2-5VM (heating only)Contrasted
Vaillant VM 280/2-5VM (heating only)Contrasted
Vaillant VM 282/2-5VM (heating only)Contrasted
Vaillant VM 202/2-5VM (heating only)Contrasted
Vaillant VMI 280-7VMI (compact interior)Contrasted
Vaillant VMI 282-7VMI (compact interior)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020034604 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020034604. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 0020034604 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start at all, with no lights or display.

    Cause: The fuse or the input stage of the PCB has failed and cuts off the supply to the rest of the circuit.

    Visually check the fuse on the PCB before replacing it entirely.

  • 02

    A lockout code appears and it needs to be reset manually every time.

    Cause: The control electronics detect a fault condition and do not clear it automatically.

    Note the exact code on the screen and consult the manufacturer's fault table before replacing the PCB.

  • 03

    The fan does not start, or it spins but the boiler does not ignite.

    Cause: The PCB is not properly sending the control signal to the fan or is not validating its speed.

    Check that the fan spins freely and quietly before holding the PCB responsible.

  • 04

    The boiler modulates poorly, fluctuating between a lot and a little heat.

    Cause: The flame control on the PCB is not properly regulating the signal to the gas valve.

    Check the gas pressure and the condition of the burner before blaming the PCB.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.63EEPROM error: fault in the configuration memory of the boiler's electronics.The EEPROM physically resides on this main PCB; if the memory becomes corrupted or fails, the cause is the board itself. Verify: after a reset, the code persists and, with correct connections and sensors, the fault reproduces; confirm replacement of the board.
F.64Electronics error / NTC: fault in the electronics or short circuit in the flow/return NTC sensors.When a short circuit in the NTC is ruled out (by checking sensors and wiring with a multimeter), the fault in the electronics processing those signals points to this main PCB. Verify: NTC and connections are correct but the fault code persists after reset = defective PCB.
F.65Temperature error in the electronics: the PCB is overheating.The temperature sensor of the electronics itself detects excess heat on the PCB; if an external heat source or lack of ventilation is ruled out, the origin is a defect in the PCB. Verify: normal environment/ventilation but the code repeats = faulty PCB.
F.61Fault in the regulation/activation of the gas valve: the electronics cannot control the gas valve.The PCB is the one that controls the gas valve; with wiring to ground, short circuit, and the valve itself ruled out using a multimeter, the remaining documented cause is the PCB. Verify: wiring and valve coils are correct but the code persists = defective PCB (the PCB is one of the causes, not the only one).
F.62Gas valve error due to delayed shutdown: delayed disconnection of the gas valve detected.The PCB manages the closing/timing of the valve and the electrode signal; with the valve and detection electrode ruled out, the control electronics defect points to this PCB. Verify: valve and electrode are correct but the code repeats = PCB (concurrent cause with valve/electrode).

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 0020034604 PCB.

Catalogue reference
0020034604
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Brand printed on the PCB
iD Vaillant 2001, screen printed
Main chip
Elmos 411018
Low voltage
21V
Mains voltage
230V
Fuse
T1,25
Mounting Variants (Baugr.)
712024/25/28 and 712026/27/29/30
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 0020034604

Is this PCB compatible with a Vaillant Turbomax Plus 824E?
Yes, the Turbomax Plus 824E is on the list of compatible boilers for this PCB.
What chip does the PCB of the Vaillant VMW 242/2-5 have?
Install an Elmos 411018 chip.
Which fuse should be checked on this PCB before installing it in a VU 282/2-5?
The PCB has a T1.25 fuse.

Spare parts related to Vaillant VMW (combi turboTEC/turboMAX, wall-mounted combi)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Vaillant Turbomax Plus 824E PCB - Ref. 0020034604