| F.61 | Error: gas valve control | The PCB may not switch or correctly read the activation signal of the valve (relay/power stage or damaged track), causing an actuation fault. Check the voltage at the valve terminals during start-up and continuity/current from the control board; if the valve and wiring are OK, suspect the PCB. |
| F.62 | Error: gas valve disconnection controller | If the output stage of the PCB gets "stuck" or delayed, it keeps the gas valve energized after the flame extinguishes, causing the disconnection delay. Check with diagnostics the de-energization time and if there is any residual power to the valve; if the valve closes properly, the cause is usually in the PCB. |
| F.63 | Fault: EEPROM | Corruption or fault in the memory circuit on the PCB; the control locks the equipment. Check power supplies and grounds; if the fault persists after reset/parameterization, replace the PCB. |
| F.64 | Fault: PCB / sensor / analog to digital transformer | A/D reading fault or PCB electronics interpreting short circuits in NTC/inputs. Check NTCs and wiring; if sensors and 5V reference are correct, the fault is in the PCB. |
| F.67 | Electronic/flame fault (implausible flame signal) | The flame control electronics (ASIC/ionization stage on the PCB) interprets an implausible signal. Check the ionization electrode/cable and grounding; if they are correct, check the signal at the PCB terminals and replace the PCB if the processing fails. |
| F.70 | Invalid product code (DSN) | After replacing the display and/or PCB without reconfiguring DSN or with incorrect coding resistance on the board, the unit locks. Verify/adjust DSN in D.93/D.97 and check the coding resistance on the PCB. |
| F.97 | Fallo en la autocomprobación de la PCB principal | The main board's self-test detects an internal fault in the PCB. Check power supply, fuses, and grounding; if it reappears, replace the PCB. |