Ignition Modulation PCB Lamborghini Inova E20 MCS W TOP Ref. 04570760
PCB for Lamborghini Calor boilers INOVA 20 C W TOP and INOVA E 20 MC W TOP. It features the Lamborghini Calor logo and includes a Schrack brand relay, although Schrack is not the manufacturer of the PCB. The manufacturer of the component, its code, and technical data could not be determined: there is no additional label reading or sources to confirm them.
Lamborghini boilers compatible with reference 04570760
PCB with reference 04570760. Compatibility confirmed with two independent sources: Inova E20 MCS W TOP. Verify the silkscreened reference on your part before purchasing.
Compatibility confirmed
| Boiler model | Family | Verification |
|---|---|---|
| Lamborghini Inova E20 MCS W TOP | Inova | Confirmed · 2 sources |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 04570760 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Locate the reference printed on the body of the PCB you have installed: it should indicate 04570760.
- Check your boiler model on the nameplate and look for it in the list of compatible models on this page.
- Compare the connections and the body with the original part before installing.
- If you have any doubts, send us a photo of the screen printing via WhatsApp and we'll confirm it for you before you purchase.
Symptoms and faults resolved by PCB 04570760
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
A click is heard on the PCB, but the boiler pump does not start.
Cause: The PCB activates the pump through a relay; if that relay is damaged or stuck, it gives the command but no current passes through.
With the boiler turned off, check that the pump shaft rotates freely by hand before attributing it to the PCB.
The boiler does not respond to any commands from the control panel.
Cause: If the microprocessor on the PCB does not start, neither the display nor the buttons have any effect.
Check that 230V are reaching the PCB and inspect the fuse before replacing it.
The boiler turns on, heats for a while, and then shuts off by itself without a clear reason.
Cause: Components of the PCB degraded by heat or humidity can cause intermittent interruptions in the control signal.
Check that the PCB does not show signs of moisture, rust, or overheated components before considering it faulty.
The domestic hot water takes a long time to arrive or does not have priority over the heating.
Cause: The PCB is the one that decides which circuit receives priority; a fault in its control logic alters that distribution.
Check that the three-way valve physically changes position when requesting domestic hot water before blaming the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Lamborghini 04570760 PCB (control board) datasheet
- OEM reference
- 04570760
- Brand
- Lamborghini
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
- The manufacturer of the PCB is not listed; only the brand Schrack can be read on a relay, which is the manufacturer of that component, not the entire PCB.
- There is no readable code or reference on the photographed label of this unit; confirm the reference of your PCB before purchasing.
- Without established technical data: there is no voltage, power, or any other confirmed value on the label or from external sources.