Saunier Duval Opalia TF 11 E Ignition PCB Ref. 0020049969

Saunier Duval Opalia TF 11 E Ignition PCB Ref. 0020049969

35 €VAT included

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with Opalia TF 11 E, Opalia TF 14 E (ref. 0020049969). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
0020049969
Brand
Saunier Duval
Type of part
PCBs (control boards)
Available units
0 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 0020049969) equips these models. Verified compatibility; check the reference before purchasing.

Opalia TF

  • Opalia TF 11 E
  • Opalia TF 14 E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F1The appliance does not start or shuts off during operation.Fault in the ignition PCB: the ignition circuit does not generate/manage the spark or the ionisation signal, or it does not control the servo valve, preventing flame establishment. Verification: check wiring and measure outputs from the PCB to the transformer/electrode and gas valve; if there is no signal and the rest of the components are correct, replace the PCB.
How do I know if this PCB is for my boiler?
Verify the reference 0020049969 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Related Spare Parts Boiler Opalia TF 11 E

Scroll to the top