Vaillant Auxiliary PCB Turboblock VCM ES 242 1 Ref. 130438

Vaillant Auxiliary PCB Turboblock VCM ES 242 1 Ref. 130438

35 €VAT includedIn stock · 3 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Compatible with VCM 182/1 E, VCM 242/1 E, VCM 282/1 E (ref. 130438). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
130438
Brand
Vaillant
Type of part
PCBs (control boards)
Available units
3 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 130438) equips these models. Verified compatibility; check the reference before purchasing.

Turboblock VCM (series /1 E)

  • VCM 182/1 E
  • VCM 242/1 E
  • VCM 282/1 E
  • VCM 240/1
  • VCM 260/1
  • VCM 180/1

VC (series /1 E)

  • VC 240/1
  • VC 242/1 E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.61Gas valve activation error.The relay/output stage of the PCB (auxiliary/main) does not correctly switch the gas valve. Check the power supply to the valve at the terminals, continuity of the harness, and if everything is correct, replace the PCB to confirm.
F.62Delay in gas valve disconnection.The PCB keeps the gas valve energized longer than it should (control/relay fault). Check that the valve closes properly and that the wiring is correct; if the issue persists, measure the control voltage and confirm by replacing the PCB.
F.63Fault: EEPROM (electronics).Corruption/defect of the EEPROM memory on the PCB. Check resets and parameters; the standard check is to replace the board with a new or programmed one to rule out the fault.
F.64Fault in the electronics/NTC.Fault in the measurement/ADC stage or sensor power supply on the PCB. Check NTC and wiring; if the sensors measure correctly but the fault code persists, the cause is the PCB.
F.65Fault: electronics temperature too high.The thermal sensor on the PCB detects overheating or the PCB itself is damaged. Check ventilation/location and temperatures; if they are normal and the error repeats, replace the PCB.
F.67Fault: electronics/flame (flame signal not plausible).The detection/ionization stage on the PCB delivers an incoherent signal. Check the electrode, cable, and polarity; if everything is correct, the fault is in the PCB.
How do I know if this PCB is for my boiler?
Verify the reference 130438 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Auxiliary Boiler Turboblock VCM ES 242 1

Scroll to the top