Vaillant PCB VCM ES 180 X Ref. 130398

Vaillant PCB VCM ES 180 X Ref. 130398

80 €VAT includedIn stock · 2 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with VC 240, VCM 180, VCM 240 (ref. 130398). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
130398
Brand
Vaillant
Type of part
PCBs (control boards)
Available units
2 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 130398) equips these models. Verified compatibility; check the reference before purchasing.

Vaillant VC/VCM atmospheric (open chamber, wall-mounted boiler)

  • VC 240
  • VCM 180
  • VCM 240
  • VCM 260

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.61Gas valve activation errorThe PCB controls the gas valve coil; if the driver/output on the board is faulty, the valve does not receive a command and cannot be activated. Check the voltage at the valve during demand and, with wiring/valve OK, check or replace the PCB.
F.62Gas valve disconnection delayThe switching element of the PCB that cuts the valve may become 'stuck', causing a delayed shutdown. Check for voltage presence at the valve after shutdown and rule out parasitic light/gas leak; if it persists, check the PCB.
F.63Fault: EEPROMMemory error in the PCB (corruption/defect). If it persists after a reset and sensors/wiring are correct, replace/program the PCB according to the manual.
F.64Electronic fault / NTCIf the flow/return NTC sensors and their harness are correct, the fault is in the measurement/ADC stage on the PCB. Check the ohms of the NTC at the terminals and continuity; with plausible readings, the cause is the control board.
F.65Fault: PCB temperatureOvertemperature or PCB electronics fault (thermal sensor/power stage). Check for external thermal influences and dissipation; if normal, check or replace the PCB.
F.67Fault: electronics/flameFlame signal not plausible due to a fault in the flame control electronics of the PCB. Check electrode, grounding, and ionization microamperage; with correct readings, the PCB is responsible.
F.70Invalid appliance code (DSN: "Device Specific Number")It appears after replacing the PCB (and/or display) without reprogramming the DSN of the model; the board remains without valid identification. Check in diagnostic d.93 and configure the correct DSN; if it doesn't accept, the board is either not suitable or is defective.
How do I know if this PCB is for my boiler?
Verify the reference 130398 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.