| F.27 | Safety shutdown: flame detection error (flame simulation). | The PCB 0020136649 incorporates flame control; if its ionization/ASIC circuit is damaged (moisture/drift), it may interpret a non-existent flame. Check the ionization signal on the PCB and rule out electrode/cable and leaks in the gas valve. |
| F.61 | Gas valve activation/control error. | Gas driver/output fault on PCB 0020136649 prevents proper supply to the valve. Check voltage/signal from the PCB to the valve connector and rule out wiring and valve. |
| F.62 | Gas valve disconnection delay. | A defect in the electronics of PCB 0020136649 may keep the valve energized longer than necessary. Check that the closing signal from the PCB drops in time and that there is no parasitic light/defective valving. |
| F.63 | Fault: EEPROM (memory). | Corruption/read-write of the EEPROM on the PCB 0020136649. Confirm with diagnosis, attempt reprogramming/adjustment and, if it persists, replace the PCB. |
| F.64 | Error: electronics / sensor (A/D/NTC transformer). | Fault in the measurement electronics of PCB 0020136649 causes implausible NTC/analogue input readings. Check NTC/wiring and measure inputs on the PCB; if they are correct, the PCB is faulty. |
| F.65 | Error: electronics temperature too high. | Overheating or internal fault in the electronics of PCB 0020136649. Check ventilation/environment, temperature in the electronic box, and inspect the PCB for discolorations/damage. |
| F.67 | Fault: electronics/flame (flame signal not plausible). | Flame signal processing error by the electronics of PCB 0020136649. Check grounding, electrode/cable, and if ionisation is correct, replace PCB. |
| F.70 | Invalid product/appliance code (DSN). | After replacing the display and PCB 0020136649 simultaneously without reprogramming the DSN, the boiler enters F.70. Verify and enter the correct DSN in D.93 according to the model manual. |