Water Pressure Sensor Fagor FE 24E N Huba Control Ref. MU1033700

Water Pressure Sensor Fagor FE 24E N Huba Control Ref. MU1033700

25 €VAT includedIn stock · 5 units

Pressure sensor: refurbished spare part that measures water pressure for the electronics. Useful if there is a pressure fault even though the pressure gauge reads correctly. Compatible with FE18E/1 B, FE18E/1 N, FE20E/2 B (ref. MU1033700). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
MU1033700
Brand
Fagor
Type of part
Pressure sensors
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. MU1033700) equips these models. Verified compatibility; check the reference before purchasing.

Fagor SuperCompact FE-E (electric)

  • FE18E/1 B
  • FE18E/1 N
  • FE20E/2 B
  • FE20E/2 N
  • FE20EF/2 LPG
  • FE20EF/2 N
  • FE24E H/1 N
  • FE24E/1 B
  • FE24E/1 N
  • FE24EC/1 B
  • FE24EC/1 N
  • FE24EMA/1 B
  • FE24EMA/1 N
  • FE26E/1 B
  • FE26E/1 N
  • FE27E/1 B
  • FE27E/1 N
  • FE27ECN/1 N
  • FE27EMA/1 B
  • FE27EMA/1 N
  • FE28E/1 B
  • FE35EMA/1 N
  • FE35EMA/1GLP

Fagor FEE

  • FEE20/2 B
  • FEE20/2 N
  • FEE24MA/1 B
  • FEE24MA/1 N
  • FEE26MA/1 B
  • FEE26MA/1 N
  • FEE27MA/1 B
  • FEE27MA/1 N
  • FEE28/1 B
  • FEE35MA/1 N
  • FEE35MA/1GLP
  • FEE35PL/1GLP
  • FEE35PLAT/1N
  • FEE40MA/1 N
  • FEE40MA/1GLP

Fagor FES

  • FES28AE/1 B
  • FES28AE/1 N

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F3Circuit pressure out of range (low/high).The water pressure switch/transducer (MU1033700) may send an incorrect reading or fail to activate the contact, causing the PCB to detect low/high pressure and lock out. Verify by comparing the gauge vs. display and measuring the sensor signal (≈0.5–3.5 V) or use a jumper/test spare part.
How do I know if this pressure sensor is the one for my boiler?
Verify the reference MU1033700 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The pressure sensor measures the water pressure of the circuit for the electronics.
Pressure fault even though the pressure gauge reads correctly?
The sensor is not transmitting the correct pressure to the PCB.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector and the gasket.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Related Spare Parts Boiler FE 24E N Huba Control

Scroll to the top