Ariston Air Pressure Switch 998484 01

Ariston Air Pressure Switch 998484 01

Ref. 998484-01

25 €VAT includedIn stock · 1 unit

Pressure switch: refurbished spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Reference 998484-01. Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
998484-01
Brand
Ariston
Type of part
Pressure switches
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
E33The air pressure switch is closed before the ignition sequence.The pressure switch remains closed at rest (membrane stuck or wiring/connections reversed). Check with a multimeter that it is open at rest and inspect/clean the connections and pressure tubes.
E34The air pressure switch does not close when the fan operates.The pressure switch does not change state when the fan starts (contacts open due to internal fault or insufficient ΔP). Check continuity during start-up and measure depression with a differential manometer; inspect pressure tubes/connections.
607Authorization of the flue pressure switch preceding the ignition sequence.The pressure switch appears 'ON' when it shouldn't (contacts stuck or connections improperly made). Verify that it is open at rest and that the connections do not create undue depression.
608No authorization from the flue gas pressure switch with the fan on.The pressure switch does not close despite the fan turning (defective diaphragm/switch or insufficient ΔP). Check continuity when starting and measure ΔP; inspect tubes and chimney obstructions.
6P1Delay in air pressure switch authorization.The pressure switch takes time to close due to being sluggish or due to limit depression. Check the closing time with a multimeter and measure ΔP during pre-ventilation; clean/adjust connections.
6P2Air pressure switch opening during operation.The pressure switch opens during operation (unstable contact or draft/pressure drop). Check continuity in operation and measure sustained ΔP; inspect tubes, obstructions, and the pressure switch itself.

Spare Parts Related Boiler 998484 01

Scroll to the top