Fagor Air Pressure Switch CE 30 E N Ref. N49G009M8

Fagor Air Pressure Switch CE 30 E N Ref. N49G009M8

25 €VAT includedIn stock · 5 units

Pressure switch: refurbished spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Reference N49G009M8. Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
N49G009M8
Brand
Fagor
Type of part
Pressure switches
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F2False pressure (air/gas evacuation pressure switch)The air pressure switch does not change state due to lack of depression in the flue circuit or internal fault; check continuity at terminals during start-up and depression in the tubes/venturi, along with the condition of the fan and chimney.