Fagor Air Pressure Switch Contract CE 20E 1N Ref. MU1289600

Fagor Air Pressure Switch Contract CE 20E 1N Ref. MU1289600

25 €VAT includedIn stock · 5 units

Pressure switch: refurbished spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Compatible with CE 20E 1N, CE 20E 1 GLP, FEB 20E 1N (ref. MU1289600). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
MU1289600
Brand
Fagor
Type of part
Pressure switches
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. MU1289600) equips these models. Verified compatibility; check the reference before purchasing.

Fagor CE 20E (Contract / series CE20E)

  • CE 20E 1N
  • CE 20E 1 LPG

Fagor FEB 20E (Ecoplus / FEB20E series)

  • FEB 20E 1N
  • FEB 20E 1G
  • FEB 20E F 1N
  • FEB 20E F 1GLP
  • FEB 20E H 1N
  • FEB 20E UK 1N
  • FEB 20E UK 1PR

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F2Air pressure switch lockout: correct circulation/status of the pressure switch not detected at start-up.The air pressure switch does not change state (internal defect, blocked tubes, or reversed connections), so the PCB detects a lack of draft; check continuity COM-NO with the fan running and inspect/vacuum the pressure intake and hoses.
How do I know if this pressure switch is for my boiler?
Verify the reference MU1289600 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The pressure switch controls the pressure/draught (of air in sealed systems) or water to authorize operation.
Is the boiler not starting or showing a draught fault?
If the fan spins but does not ignite, check the pressure tubes (loose/blocked), the diaphragm, and the fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the tightness of the pressure pipes and the switching of the contact.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.