Fumes Pressure Switch Fagor Ecomini FEB 24AR Ref. AS0003109

Fumes Pressure Switch Fagor Ecomini FEB 24AR Ref. AS0003109

15 €VAT includedIn stock · 4 units

Pressure switch: refurbished spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Compatible with FE-24NOX/1B, FE 24 NOX/1B, FEB 24AR/1 N (ref. AS0003109). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
AS0003109
Brand
Fagor
Type of part
Pressure switches
Available units
4 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. AS0003109) equips these models. Verified compatibility; check the reference before purchasing.

Fagor FE NOx

  • FE-24NOX/1B
  • FE 24 NOx/1B

Fagor Ecomini FEB AR

  • FEB 24AR/1 N
  • Ecomini FEB 24AR

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F02Flue/air evacuation fault (the unit does not confirm draft).The differential pressure switch (AS0003109) does not switch because it does not reach the fan's depression or is faulty; the PCB does not receive the 'draft OK' signal and locks in F02. Check with a vacuum gauge/manometer at the ports and measure continuity at the pressure switch terminals during startup, as well as inspect the tubes and Venturi.
How do I know if this pressure switch is for my boiler?
Verify the reference AS0003109 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The pressure switch controls the pressure/draught (of air in sealed systems) or water to authorize operation.
Is the boiler not starting or showing a draught fault?
If the fan spins but does not ignite, check the pressure tubes (loose/blocked), the diaphragm, and the fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the tightness of the pressure pipes and the switching of the contact.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Related Spare Parts Boiler Ecomini FEB 24AR

Scroll to the top