Fumes Pressure Switch Fagor FE 11DL N Ref. 810006759

Fumes Pressure Switch Fagor FE 11DL N Ref. 810006759

25 €VAT includedIn stock · 1 unit

Pressure switch: refurbished spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Compatible with FE-11DL1B, FE11D1N, FE11DPL1B (ref. 810006759). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
810006759
Brand
Fagor
Type of part
Pressure switches
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 810006759) equips these models. Verified compatibility; check the reference before purchasing.

Fagor FE (water heaters)

  • FE-11DL1B
  • FE11D1N
  • FE11DPL1B

Fagor FEC (water heaters)

  • FEC11TD1N

Fagor AQUAPRO (water heaters)

  • AQUAPRO-11E1N

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F2Fault in air circulation detection by the flue/air pressure switch.The flue pressure switch (810006759) does not switch because there is insufficient depression or it is faulty; the PCB does not validate the draft and locks. Check with a differential manometer and inspect the pressure switch tubes, fan, and flue duct; for a specific test, check with a temporary bypass of the pressure switch (diagnostic only).
How do I know if this pressure switch is for my boiler?
Verify the reference 810006759 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Huba part.
What is it used for?
The pressure switch controls the pressure/draught (of air in sealed systems) or water to authorize operation.
Is the boiler not starting or showing a draught fault?
If the fan spins but does not ignite, check the pressure tubes (loose/blocked), the diaphragm, and the fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the tightness of the pressure pipes and the switching of the contact.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.