Pressure switch Water Cointra Edyco ED 21 EI Ref. 9158230

Pressure switch Water Cointra Edyco ED 21 EI Ref. 9158230

30 €VAT includedIn stock · 5 units

Pressure switch: reconditioned spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Compatible with SP 27 EI, SPA 27 EI, SP 21 EI (ref. 9158230). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
9158230
Brand
Cointra
Type of part
Pressure switches
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 9158230) equips these models. Verified compatibility; check the reference before purchasing.

Supra

  • SP 27 EI
  • SPA 27 EI
  • SP 21 EI
  • SP 21 I

Edyco

  • ED 21 EI
  • ED 21 I

Europe

  • E 24 I
  • M 24 I

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
5Indicates lack of water or blocked pump.The minimum hydraulic differential pressure switch does not give consensus due to insufficient pressure/flow or a fault in the pressure switch itself; check pressure (≈0.5–1 bar), bleed the circuit, and check continuity/micro of the pressure switch.
LED 2 Off + LED 3 Slow FlashingLack of water in the heating circuit or blocked pump.The hydraulic differential pressure switch (lack of water) prevents consensus; check pressure and bleed the circuit, and test the micro/continuity of the pressure switch.
How do I know if this pressure switch is for my boiler?
Verify the reference 9158230 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The pressure switch controls the pressure/draught (of air in sealed systems) or water to authorize operation.
Is the boiler not starting or showing a draught fault?
If the fan spins but does not ignite, check the pressure tubes (loose/blocked), the diaphragm, and the fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the tightness of the pressure pipes and the switching of the contact.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.