Fagor Circulating Pump Motor FE 24AE 1N Ref. MU0500117
RefurbishedFagorPumps

Fagor Circulating Pump Motor FE 24AE 1N Ref. MU0500117

60 €VAT includedIn stock · 7 units

Circulating pump: refurbished spare part that circulates the water in the heating circuit. Useful if there is noise, the water does not circulate, or the radiators do not heat evenly. Compatible with FE 24AE 1N, FE 24E N, Super Compact FE 24E (ref. MU0500117). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
MU0500117
Brand
Fagor
Type of part
Pumps
Available units
7 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. MU0500117) equips these models. Verified compatibility; check the reference before purchasing.

Fagor FE / Super Compact / Super Comfort 24

  • FE 24AE 1N
  • FE 24E N
  • Super Compact FE 24E
  • Super Comfort FE 24E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F1Lockout due to ignition fault.The gas valve does not open/modulate correctly and there is not enough flow to form/stabilise the flame; check the power supply to the solenoid valves (on/off and modulating), inlet pressure, and that the ramp delivers pressure when ignition starts.
F6Flame detection with the burner off (false flame/persistent flame).The gas valve does not close completely and allows gas to pass, maintaining a flame when it shouldn't; check the valve's tightness at rest (manometer on the manifold) and ensure that when the demand is cut, the pressure in the manifold drops to 0 and there is no residual control voltage to the solenoid valves.
F10Fault in the control/closure of the gas valve.Mechanical or electrical fault of the valve (coils, on/off solenoids, or control module); check coil continuity, control voltage during opening/closing, and response in self-test; if there is a stuck relay on the PCB, rule it out first.
How do I know if this circulating pump is the one for my boiler?
Verify the reference MU0500117 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The circulating pump circulates the water through the heating circuit.
Noise, water not circulating, or cold radiators?
Typical symptoms: humming, seized rotor after a long stop, or radiators that do not heat evenly.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Bleed the air from the circuit and the pump; check the pressure at 1–1.5 bar with the boiler cold.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.