Saunier Duval Thelia Twin 28 E Module Ref. 05602400

Saunier Duval Thelia Twin 28 E Module Ref. 05602400

25 €VAT includedIn stock · 5 units

Ignition transformer: refurbished spare part that generates high voltage for the spark of the electrodes. Useful if there is no spark or ignition faults are repeated. Reference 05602400. Includes a one-year warranty. Delivery time and cost are shown at checkout for the destination country.

1
Consult via WhatsApp
Delivery calculated by destination
1-year warranty
14-day return
Technical support

Key Data

Reference
05602400
Brand
Saunier Duval
Type of part
Transformers
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.26Fault: gas valve not functioning.The ignition control board governs the stepper motor of the gas valve; if its control stage fails, the valve does not respond and the unit locks out. Verification: measure the control signal to the stepper motor during the ignition attempt; if there is no signal and the wiring/valve assembly are OK, the board is defective.
F.27Safety shutdown: incorrect flame detection.Fault in the flame control electronics integrated in the PCB (ionisation), which simulates or fails to detect a flame. Verification: check ionisation current (≈2–8 μA) and grounding; if electrodes/wiring are correct and the issue persists, replace the PCB.
F.28Start-up fault: ignition failed.If the ignition PCB does not excite the spark transformer or does not manage ionisation, the start-up fails despite having correct gas. Verification: check HV output to ignition transformer and ionisation signal; if they are missing and gas/electrodes are OK, the PCB is the cause.
F.61Gas valve control/activation fault.The output stage of the PCB controls the valve; an electronic defect prevents its correct activation. Verification: measure the control voltage to the valve during ignition; if it is non-existent or erratic and the valve/wiring are correct, the PCB is faulty.
F.62Gas valve fault: disconnection delay.The circuit of the PCB should cut off the gas valve when turning off; if the stage remains 'stuck' or delays the cut-off, F.62 appears. Verification: check that the gas valve loses power instantly at the end of the flame; if not and the valve is not jammed, the PCB is the cause.
F.67Fault: electronics/flame (flame signal not plausible).The electronic processing of the ionisation signal on the PCB returns incoherent values, causing a lockout. Verification: rule out ionisation/electrodes/ground, and if the implausible reading persists, replace the ignition control board.