Vaillant ecoTEC plus VMW 32CS/1-5 C boiler
The ecoTEC plus VMW 32CS/1-5 C increases the domestic hot water service to 31.8 kW and 15.2 l/min of specific flow at ΔT 30 K. Its heating operates between 3.4 and 24.8 kW at 80/60 °C. It occupies the same space as the 26 and 36 versions, with an intermediate domestic capacity. Pack 8000014267 with sensoHOME wired. Confirm revision R1 of the supplied unit. No installation. VAT and mainland shipping included.
- Heating power (80/60 °C)
- 3.4-24.8 kW
- Specific flow rate for domestic hot water (ΔT 30 K)
- 15.2 l/min
- Dimensions (height x width x depth)
- 720 x 440 x 348 mm
The model, at a glance
Vaillant ecoTEC plus VMW 32CS: heating 3.4-24.8 kW at 80/60 °C, DHW 31.8 kW and specific flow rate 15.2 l/min at ΔT 30 K.
- Heating power (80/60 °C)
- 3.4-24.8 kW
- Specific flow rate for domestic hot water (ΔT 30 K)
- 15.2 l/min
- Dimensions (height x width x depth)
- 720 x 440 x 348 mm
Read the full description and what it includes.
The VMW 32CS occupies the midpoint of this comparison: 31.8 kW for domestic hot water compared to 25.7 kW for the 26 and 35.6 kW for the 36. In heating, it delivers from 3.4 to 24.8 kW at 80/60 °C, or from 3.9 to 27.0 kW at 50/30 °C. The choice depends on the heat losses of the home and the hot water needed, not just on the number of rooms.
Micro-accumulation enhances the initial response of hot water. The specific flow rate is 15.2 l/min at ΔT 30 K, while the commercial sheet states 18.2 l/min at ΔT 25 K: the second figure uses a lower heating, not an additional performance. There is also a limiter of 10.4 l/min that must be taken into account when assessing various consumptions.
The commercial orientation for two or three bathrooms and a kitchen does not guarantee simultaneous showers. The body has a depth of 348 mm and requires the indicated maintenance clearances. Compared to the 36, it maintains the same format, with a lower minimum heating power: 3.4 kW versus 3.9 kW of the 36 at 80/60 °C.
What is included in the purchase?
Pack 8000014267 with sensoHOME wired. Confirm revision R1 of the supplied unit. Without installation.
Price including VAT and shipping to mainland Spain. Installation, adaptations, and commissioning are valued separately.
What to check before installing this boiler
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
- Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
- Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
- Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Technical data of Vaillant ecoTEC plus VMW 32CS/1-5 C boiler
- Brand
- Vaillant
- Model
- Vaillant ecoTEC plus VMW 32CS/1-5 C boiler
- Status
- New
- Supply scope
- Pack 8000014267 with sensoHOME wired. Confirm revision R1 of the supplied unit. Without installation.
- Shipping
- Included in mainland Spain. Please confirm the deadline.
- Commercial reference
- 8000014267
Specifications and dimensions of the model
Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.
- Heating power G20 (80/60 °C)
- 3.4-24.8 kW
Heating - Heating power G20 (50/30 °C)
- 3.9-27.0 kW
Heating - Heating thermal load G20 (Hi)
- 3.7-25.5 kW
Heating - Adjustable flow temperature
- 30-80 °C
Heating - Maximum heating pressure
- 3 bar
Heating - Maximum power DHW G20
- 31.8 kW
Hot water - Nominal thermal load DHW G20 (Hi)
- 32.6 kW
Hot water - Specific flow rate D (ΔT 30 K, EN 13203-1)
- 15.2 l/min
Hot water - Declared domestic hot water flow rate (ΔT 25 K)
- 18.2 l/min
Hot water - Minimum starting flow rate
- 2 l/min
Hot water - Domestic hot water flow limiter
- 10.4 l/min
Hot water - Adjustable domestic hot water temperature
- 35-65 °C
Hot water - Allowed service pressure for domestic hot water
- 0.3-10 bar
Hot water - Required connection pressure for domestic hot water
- 0.7 bar
Hot water - Hot water system
- Mixed with micro-accumulation
Hot water - Heating energy class
- A
Energy and control - Energy class of domestic hot water
- A
Energy and control - Sanitary profile
- XL
Energy and control - Standby power consumption
- Less than 2 W
Energy and control - myVAILLANT connectivity
- Optional Plug & Play
Energy and control - Dimensions (height x width x depth)
- 720 x 440 x 348 mm
Dimensions and installation - Minimum lateral distance
- 5 mm on each side
Dimensions and installation - Minimum inferior distance
- 180 mm
Dimensions and installation - Minimum front service distance
- 500 mm
Dimensions and installation - Superior distance with 60/100 outlet
- 165 or 248 mm, according to the installation plan
Dimensions and installation - Higher distance with outlet 80/80
- 220 mm
Dimensions and installation - Maximum distance with outlet 80/125
- 276 mm
Dimensions and installation - Natural gas connection pressure G20
- 20 mbar
Gas
PDF and documentation of the model
Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.
- ecoTEC plus VM/VMW installation manualPDF · 96 pages · VaillantView original on the manufacturer's website ↗
- ecoTEC plusPDF · 2 pages · VaillantView original on the manufacturer's website ↗
The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.