Representación ilustrativa Conductos 1×1: PEAD-SM100JA + PUZ-SM100VKA. Capacidad en frío: 9.5 kW, aproximadamente 8170 frigorías por hora. Capacidad en calor: 11.2 kW. Eficiencia en frío A. Consumo anual normalizado en frío: 600 kWh. Render basado en fotografías de referencia; originales en la galería, no a escala.

Mitsubishi Electric ducted air conditioning PEAD-SM100JA + PUZ-SM100VKA

Shipping included to mainland Spain · delivery in 24–48 h. Installation not included.

VAT includedAvailable · delivery in 24–48 h

Ducted air conditioning Mitsubishi Electric: PEAD-SM100JA + PUZ-SM100VKA. 1 × PEAD-SM100JA (indoor unit); 1 × PUZ-SM100VKA (outdoor unit); 1 × PAR-41 (remote control). Installation not included. The PEAD-SM100JA with PUZ-SM100VKA is the single-phase ducted pair with a nominal cooling capacity of 9.5 kW and heating capacity of 11.2 kW. Its indoor unit measures 250 × 1,400 × 732 mm; the space required for ducts, return, and maintenance must be checked in the project. For PEAD-SM100JA + PUZ-SM100VKA, the sources indicated in the table document SEER 5.3 and SCOP 3.8 in moderate climate. These are normalized data for the set, not a constant performance or a promise of expenditure in any installation. The supplier's rate states that a PAR-41 remote control is included. The finish and extended name of the variant are not specified in that source. A single figure for normalized annual consumption in cooling, normalized annual consumption in heating · moderate climate is not published: the manufacturer editions consulted differ and the applicable revision is not identified. The published figures identify their sources; this documentary review does not verify the serial number or the physical content of the order.

Components and supply

What is included in PEAD-SM100JA + PUZ-SM100VKA?

The composition identifies each reference and quantity. It does not replace the compatibility table for other combinations.

ModelComponentSupply scope
PEAD-SM100JAIndoor unit
Ducted indoor unit
1 included
PUZ-SM100VKAOutdoor unit
Outdoor unit of this 1×1 pair, single-phase power supply.
1 included
PAR-41Control board
PAR-41 remote included. The supplier's price list does not specify the suffix or finish for this reference.
1 included

Additional accessories not explicitly specified in the order Installation work and materials not explicitly budgeted

The images maintain the reference or family scope indicated in their description; they do not certify stock availability or the serial number that will be supplied.

Guide

What to check before installing PEAD-SM100JA + PUZ-SM100VKA

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Check the references PEAD-SM100JA + PUZ-SM100VKA and the revision of their labels before replacing units.
  2. Evaluate the thermal demand, distribution, insulation, and location before selecting ducted air conditioning.
  3. Check dimensions, clearances, power supply, and travel with the specific documentation and a qualified installer.
  4. The budget must separate equipment, materials, assembly, and commissioning.
Technical data

PEAD-SM100JA + PUZ-SM100VKA

Brand
Mitsubishi Electric
Model and composition
PEAD-SM100JA + PUZ-SM100VKA
Supply scope
1 × PEAD-SM100JA (indoor unit); 1 × PUZ-SM100VKA (outdoor unit); 1 × PAR-41 (remote control)
Installation
Not included
Availability and transport
New equipment available. VAT and shipping included to mainland Spain · delivery in 24–48 h. Installation not included. Not shipped to islands, Ceuta, Melilla, or abroad.

Specifications and dimensions of the model

Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.

Nominal power in cold conditions
9.5 kW
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Nominal heat output
11.2 kW
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Power supply / phase
Single-phase
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Refrigerant
R32
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1.
SEER of the set
5,3
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · Technical specifications Ducts PEAD, edition not indicated, consulted copy on September 7, 2026, PDF 1.
SCOP of the set · average climate
3,8
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · Technical specifications Ducts PEAD, edition not indicated, consulted copy on September 7, 2026, PDF 1.
Energy class in cold
A
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · Technical specifications Ducts PEAD, edition not indicated, consulted copy on September 7, 2026, PDF 1.
Energy class in heating · average climate
A
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · Technical specifications Ducts PEAD, edition not indicated, consulted copy on September 7, 2026, PDF 1.
Indoor unit · height × width × depth
250 × 1,400 × 732 mm
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Body dimensions, no mounting reserve; check protrusions, clearances and accessories in the plan.
Weight of the indoor unit
39 kg
Units bodies, acoustics, and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, document consulted on September 7, 2026, PDF 1.
Interior sound pressure in cold
29 / 34 / 38 dB(A)
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Values by fan speed; sound pressure, not sound power.
Outdoor unit · height × width × depth
981 × 1,050 × 330 mm
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Body dimensions, no mounting reserve; check protrusions, clearances and accessories in the plan.
Weight of the outdoor unit
76 kg
Units bodies, acoustics, and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, document consulted on September 7, 2026, PDF 1.
External sound pressure in cold conditions
51 dB(A) in cold
Units bodies, acoustics, and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Nominal value in cooling; not extrapolated to heating.
Nominal electrical power in cold conditions
2.95 kW
Electric power and operation at different loads · Electricity consumed under nominal testing conditions; it is not a constant consumption nor a data in kWh/year.
Nominal electric power in heat
3.02 kW
Electric power and operation at different loads · Electricity consumed under nominal conditions; it should not be confused with the thermal power delivered.
EER / nominal COP
3,21 / 3,7
Electric power and operation at different loads · Efficiency ratios under nominal conditions; they are not SEER/SCOP and do not guarantee that performance at any temperature.
Cold capacity range
4 to 10.6 kW
Electric power and operation at different loads · Minimum and maximum capacity published for this exact pair. It does not represent its electrical consumption.
Heating capacity range
2.8 to 12.5 kW
Electric power and operation at different loads · Minimum and maximum capacity from the catalog; it is not a covered area nor a constant power under any external conditions.
Design heat load at -10 °C (Pdesign)
8 kW
Electric power and operation at different loads · Design load for heating at the indicated reference temperature. This is a value different from the nominal capacity in heat.
Airflow of the indoor unit
24 / 29 / 34 m³/min
Airflow and available pressure · Values for low, medium, and high speed, in the order L/M/H from the manufacturer's table.
Selectable static pressure
35 / 50 / 70 / 100 / 150 Pa
Airflow and available pressure · Settings published by Mitsubishi; they do not guarantee the same airflow with any length or duct pressure loss.
Air flow of the outdoor unit
79 m³/min
Airflow and available pressure · Data from the outdoor unit, not ventilation or air renewal flow.
Supply voltage
230 V
Electrical and refrigeration connections · This pair is single-phase. Check the actual power supply before installation.
Maximum intensity of the set
22.7 A
Electrical and refrigeration connections · Value of the row Voltage/Phases - Maximum Current. This is not the rating of the circuit breaker: the line and protections must be sized for the installation.
Pipe diameters · liquid / gas
9.52 / 15.88 mm
Electrical and refrigeration connections · Liquid/gas order from the catalog. Check materials, insulation, connections, and exact review in the installation manual.
Maximum pipe slope
30 m
Electrical and refrigeration connections · Published vertical limit for the pair; also check the layout and restrictions in the manual.
Maximum total pipe length
30 m
Electrical and refrigeration connections · Actual pipe run, not straight-line distance. These are not meters included in the purchase nor a confirmation that the pre-charge covers the entire run.
Factory refrigerant pre-charge
3.1 kg of R32
Electrical and refrigeration connections · Factory quantity published by Mitsubishi. The additional load depends on the run and the manual of the outdoor unit; it is not calculated here by assumption.
Cold operation outdoor range
-15 to 46 °C
Installation and operating limits · For cooling with an outdoor environment below -5 °C, the catalog requires an optional wind protection guide. The range does not guarantee nominal power at all points.
Operating temperature range for heating
-15 to 21 °C
Installation and operating limits · Published outdoor operating temperatures; they do not equate to a guarantee of nominal capacity across the entire range.
Nominal pipe length of the test
5 m
Installation and operating limits · Length used by the manufacturer to calculate capacity under nominal conditions; it is not pipe supplied with the assembly.
Maximum number of curves
15
Installation and operating limits · Limit indicated in the catalog notes. It should be reviewed along with the length, the elevation difference, and the installation manual.
Dehumidification limit
It does not work below 13 °C in the room.
Installation and operating limits · Condition expressly stated by Mitsubishi in the notes of this series; do not confuse it with the outdoor operating range.
Drain pump
Incorporated
Installation and operating limits · Performance indicated on the page of this series. The drainage pipe, its execution, and the permissible height are reviewed during installation.
Condensate control
Incorporated
Installation and operating limits · The catalog indicates that it is incorporated in the units. It does not replace the wind protection required for certain uses in cold conditions.
Additional indication for exterior background
(+40) mm according to the catalog
Installation and operating limits · The table shows the overall dimension as 981 × 1,050 × 330 (+40) mm. Complete the previously published body measurements; it is not a maintenance clearance nor is it attributed to a specific part without a drawing.
Remote control included
PAR-41 remote included. The supplier's price list does not specify the suffix or finish for this reference.
Remote control and connectivity
Wi-Fi
Wi-Fi is not included in this offer. Mobile control requires a compatible accessory; its reference must be verified for the specific equipment.
Remote control and connectivity
Before purchasing
  • The unit, condition, and source of each value from the original catalog are preserved. The indicated editions and revisions define their scope; missing figures are not completed by analogy. Uniclima's commercial conditions are validated separately.
Documentation

Manuals and technical documentation

Official sources from the manufacturer. Cross-check the model and the revision of the labels of both units.

Frequently Asked Questions

Questions about PEAD-SM100JA + PUZ-SM100VKA

What does PEAD-SM100JA + PUZ-SM100VKA include?
1 × PEAD-SM100JA (indoor unit); 1 × PUZ-SM100VKA (outdoor unit); 1 × PAR-41 (remote control). The previous composition identifies the units and controls of this offer. The installation is contracted separately.
What measurements should I check before booking the equipment?
Indoor unit · height × width × depth: 250 × 1,400 × 732 mm. Outdoor unit · height × width × depth: 981 × 1,050 × 330 mm. These are the dimensions of the indicated components, not the minimum installation space. Also allow for the clearances, connections, and maintenance access required by the manual.
How much electricity does it need and how is it distinguished from cooling power?
Nominal electrical power in cold: 2.95 kW. Nominal electrical power in heat: 3.02 kW. Thermal power describes the cold or heat delivered; electrical power is the input to the equipment. The nominal values are not a constant consumption or a forecast of the bill.
What efficiency does this combination have and what can I compare?
SEER of the set: 5.3. SCOP of the set · average climate: 3.8. Energy class in cooling: A. Energy class in heating · average climate: A. Compare the same magnitude, combination, and test climate. This data does not certify the consumption of your home or the performance of another combination.
Is Wi-Fi included or is an accessory required?
Wi-Fi is not included in this offer. Mobile control requires a compatible accessory; its reference must be verified for the specific equipment.
What command does the equipment receive?
PAR-41 remote included. The supplier's price list does not specify the suffix or finish for this reference.
Are the decibels in the technical sheet the noise I will hear at home?
Indoor sound pressure at cold: 29 / 34 / 38 dB(A). Outdoor sound pressure at cold: 51 dB(A) at cold. Maintain the indicated speed and mode when comparing. Sound pressure and sound power are different magnitudes; the perceived noise also depends on the room and the installation.
What should I check if I want to make use of my ducts?
To install PEAD-SM100JA + PUZ-SM100VKA, the technician must check the flow rate and the condition of the network, the return grilles, the drainage, and the maintenance access. Just because the unit fits does not guarantee that the ducts will properly distribute its 9.5 kW of cooling. The price does not include adapting that network.
What changes between PUZ-SM100VKA and PUZ-SM100YKA?
VKA is the single-phase version and YKA is the three-phase version of the pairs published here. Both offer 9.5 kW nominal in cold with PEAD-SM100JA; do not choose the phase based on a supposed power gain.
Does PEAD100 mean exactly 10 kW?
Not for this pair: PEAD-SM100JA + PUZ-SM100VKA publishes 9.5 kW nominal in cooling and 11.2 kW in heating. Check those data for the set, not just the number 100 of the model.
Can I choose single-phase even if I have a lot of power?
This reference VKA is single-phase, but the electrical installation must be able to supply the equipment. Before purchasing, confirm the line and the available power; single-phase does not mean that any household socket is suitable.
Can I set a different temperature in each room?
The supply includes a control for the assembly, not a room zoning system. To regulate zones independently, compatible controls and distribution elements are needed, defined separately according to the duct network.

Services for your air conditioning

Complete setCheck references and quantities.
Shipping includedMainland Spain · 24–48 h
Separate installationSpecific budget
DocumentationModel data and limits
Mitsubishi Electric ducted air conditioning PEAD-SM100JA + PUZ-SM100VKA