Representación ilustrativa Conductos 1×1: PEAD-SM125JA + PUZ-SM125YKA. Capacidad en frío: 12.1 kW, aproximadamente 10406 frigorías por hora. Capacidad en calor: 13.5 kW. Consumo eléctrico nominal: 4,17 kW en frío y 3,85 kW en calor. Alimentación: Trifásico. Render basado en fotografías de referencia; originales en la galería, no a escala.

Mitsubishi Electric ducted air conditioning PEAD-SM125JA + PUZ-SM125YKA

Shipping included to mainland Spain · delivery in 24–48 h. Installation not included.

VAT includedAvailable · delivery in 24–48 h

Mitsubishi Electric ducted air conditioning: PEAD-SM125JA + PUZ-SM125YKA. 1 × PEAD-SM125JA (indoor unit); 1 × PUZ-SM125YKA (outdoor unit); 1 × PAR-41 (remote control). Installation not included. The PEAD-SM125JA with PUZ-SM125YKA is the three-phase ducted pair with a nominal cooling capacity of 12.1 kW and heating capacity of 13.5 kW. Its indoor unit measures 250 × 1,400 × 732 mm; the space required for ducts, return, and maintenance must be checked in the project. Seasonal efficiency: cooling 210.6%; heating 150.1%. The Spanish catalog from June 2025, PDF 186, expresses these in percentage; they are not SEER/SCOP ratios nor converted into an invented energy class. The supplier's rate states that a PAR-41 remote control is included. The finish and extended name of the variant are not specified in that source. The published figures identify their sources; this document review does not verify the serial number or the physical content of the order.

Components and supply

What does PEAD-SM125JA + PUZ-SM125YKA include?

The composition identifies each reference and quantity. It does not replace the compatibility table for other combinations.

ModelComponentSupply scope
PEAD-SM125JAIndoor unit
Ducted indoor unit
1 included
PUZ-SM125YKAOutdoor unit
Outdoor unit of this 1×1 pair, three-phase power supply.
1 included
PAR-41Control board
PAR-41 remote included. The supplier's price list does not specify the suffix or finish for this reference.
1 included

Additional accessories not explicitly specified in the order Installation work and materials not explicitly budgeted

The images maintain the reference or family scope indicated in their description; they do not certify stock availability or the serial number that will be supplied.

Guide

What to check before installing PEAD-SM125JA + PUZ-SM125YKA

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Check the references PEAD-SM125JA + PUZ-SM125YKA and the revision of their labels before replacing units.
  2. Evaluate the thermal demand, distribution, insulation, and location before selecting ducted air conditioning.
  3. Check dimensions, clearances, power supply, and travel with the specific documentation and a qualified installer.
  4. The budget must separate equipment, materials, assembly, and commissioning.
Technical data

Technical sheet: PEAD-SM125JA + PUZ-SM125YKA

Brand
Mitsubishi Electric
Model and composition
PEAD-SM125JA + PUZ-SM125YKA
Supply scope
1 × PEAD-SM125JA (indoor unit); 1 × PUZ-SM125YKA (outdoor unit); 1 × PAR-41 (remote control)
Installation
Not included
Availability and transport
New equipment available. VAT and shipping included to mainland Spain · delivery in 24–48 h. Installation not included. Not shipped to islands, Ceuta, Melilla, or abroad.

Specifications and dimensions of the model

Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.

Nominal power in cold conditions
12.1 kW
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Nominal heat output
13.5 kW
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Power supply / phase
Three-phase
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Refrigerant
R32
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Normalized annual consumption in cold
898 kWh/year
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · General catalog, June 2025 edition, PDF 186. Normalized test data of the pair; it does not predict the bill or the actual consumption of the home.
Normalized annual consumption in heat · average climate
3.085 kWh/year
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · General catalog, June 2025 edition, PDF 186. Normalized test data of the pair; it does not predict the bill or the actual consumption of the home.
Published seasonal efficiency in percentage
Seasonal efficiency: cooling 210.6%; heating 150.1%.
Seasonal efficiency of this pair · Source: Mitsubishi Electric Spain · General catalog, June 2025 edition, PDF 186. The table in this edition publishes percentages: they are kept as percentages, without converting them into SEER/SCOP ratios.
Indoor unit · height × width × depth
250 × 1,400 × 732 mm
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Body dimensions, no mounting reserve; check protrusions, clearances and accessories in the plan.
Weight of the indoor unit
40 kg
Units bodies, acoustics, and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, document consulted on September 7, 2026, PDF 1.
Interior sound pressure in cold
33 / 36 / 40 dB(A)
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Values by fan speed; sound pressure, not sound power.
Outdoor unit · height × width × depth
981 × 1,050 × 330 mm
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Body dimensions, no mounting reserve; check protrusions, clearances and accessories in the plan.
Weight of the outdoor unit
85 kg
Units bodies, acoustics, and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, document consulted on September 7, 2026, PDF 1.
External sound pressure in cold conditions
54 dB(A) in cold
Units bodies, acoustics, and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Nominal value in cooling; not extrapolated to heating.
Nominal electrical power in cold conditions
4.17 kW
Electric power and operation at different loads · Electricity consumed under nominal testing conditions; it is not a constant consumption nor a data in kWh/year.
Nominal electric power in heat
3.85 kW
Electric power and operation at different loads · Electricity consumed under nominal conditions; it should not be confused with the thermal power delivered.
EER / nominal COP
2,9 / 3,5
Electric power and operation at different loads · Efficiency ratios under nominal conditions; they are not SEER/SCOP and do not guarantee that performance at any temperature.
Cold capacity range
6 to 13 kW
Electric power and operation at different loads · Minimum and maximum capacity published for this exact pair. It does not represent its electrical consumption.
Heating capacity range
4.1 to 15 kW
Electric power and operation at different loads · Minimum and maximum capacity from the catalog; it is not a covered area nor a constant power under any external conditions.
Design heat load at -10 °C (Pdesign)
8.5 kW
Electric power and operation at different loads · Design load for heating at the indicated reference temperature. This is a value different from the nominal capacity in heat.
Airflow of the indoor unit
29.5 / 35.5 / 42 m³/min
Airflow and available pressure · Values for low, medium, and high speed, in the order L/M/H from the manufacturer's table.
Selectable static pressure
35 / 50 / 70 / 100 / 150 Pa
Airflow and available pressure · Settings published by Mitsubishi; they do not guarantee the same airflow with any length or duct pressure loss.
Air flow of the outdoor unit
86 m³/min
Airflow and available pressure · Data from the outdoor unit, not ventilation or air renewal flow.
Supply voltage
400 V
Electrical and refrigeration connections · This pair is three-phase. Check the actual power supply before installation.
Maximum intensity of the set
14.3 A
Electrical and refrigeration connections · Value of the row Voltage/Phases - Maximum Current. This is not the rating of the circuit breaker: the line and protections must be sized for the installation.
Pipe diameters · liquid / gas
9.52 / 15.88 mm
Electrical and refrigeration connections · Liquid/gas order from the catalog. Check materials, insulation, connections, and exact review in the installation manual.
Maximum pipe slope
30 m
Electrical and refrigeration connections · Published vertical limit for the pair; also check the layout and restrictions in the manual.
Maximum total pipe length
40 m
Electrical and refrigeration connections · Actual pipe run, not straight-line distance. These are not meters included in the purchase nor a confirmation that the pre-charge covers the entire run.
Factory refrigerant pre-charge
3.6 kg of R32
Electrical and refrigeration connections · Factory quantity published by Mitsubishi. The additional load depends on the run and the manual of the outdoor unit; it is not calculated here by assumption.
Cold operation outdoor range
-15 to 46 °C
Installation and operating limits · For cooling with an outdoor environment below -5 °C, the catalog requires an optional wind protection guide. The range does not guarantee nominal power at all points.
Operating temperature range for heating
-15 to 21 °C
Installation and operating limits · Published outdoor operating temperatures; they do not equate to a guarantee of nominal capacity across the entire range.
Nominal pipe length of the test
5 m
Installation and operating limits · Length used by the manufacturer to calculate capacity under nominal conditions; it is not pipe supplied with the assembly.
Maximum number of curves
15
Installation and operating limits · Limit indicated in the catalog notes. It should be reviewed along with the length, the elevation difference, and the installation manual.
Dehumidification limit
It does not work below 13 °C in the room.
Installation and operating limits · Condition expressly stated by Mitsubishi in the notes of this series; do not confuse it with the outdoor operating range.
Drain pump
Incorporated
Installation and operating limits · Performance indicated on the page of this series. The drainage pipe, its execution, and the permissible height are reviewed during installation.
Condensate control
Incorporated
Installation and operating limits · The catalog indicates that it is incorporated in the units. It does not replace the wind protection required for certain uses in cold conditions.
Additional indication for exterior background
(+40) mm according to the catalog
Installation and operating limits · The table shows the overall dimension as 981 × 1,050 × 330 (+40) mm. Complete the previously published body measurements; it is not a maintenance clearance nor is it attributed to a specific part without a drawing.
Remote control included
PAR-41 remote included. The supplier's price list does not specify the suffix or finish for this reference.
Remote control and connectivity
Wi-Fi
Wi-Fi is not included in this offer. Mobile control requires a compatible accessory; its reference must be verified for the specific equipment.
Remote control and connectivity
Before purchasing
  • The unit, condition, and source of each value from the original catalog are preserved. The indicated editions and revisions define their scope; missing figures are not completed by analogy. Uniclima's commercial conditions are validated separately.
Documentation

Manuals and technical documentation

Official sources from the manufacturer. Cross-check the model and the revision of the labels of both units.

Frequently Asked Questions

Questions about PEAD-SM125JA + PUZ-SM125YKA

What is included in PEAD-SM125JA + PUZ-SM125YKA?
1 × PEAD-SM125JA (indoor unit); 1 × PUZ-SM125YKA (outdoor unit); 1 × PAR-41 (remote control). The previous composition identifies the units and controls of this offer. The installation is contracted separately.
What measurements should I check before booking the equipment?
Indoor unit · height × width × depth: 250 × 1,400 × 732 mm. Outdoor unit · height × width × depth: 981 × 1,050 × 330 mm. These are the dimensions of the indicated components, not the minimum installation space. Also allow for the clearances, connections, and maintenance access required by the manual.
How much electricity does it need and how is it distinguished from cooling power?
Nominal electrical power in cold: 4.17 kW. Nominal electrical power in heat: 3.85 kW. Thermal power describes the cold or heat delivered; electrical power is the input to the equipment. The nominal values are not a constant consumption or a forecast of the bill.
Is Wi-Fi included or is an accessory required?
Wi-Fi is not included in this offer. Mobile control requires a compatible accessory; its reference must be verified for the specific equipment.
What command does the equipment receive?
PAR-41 remote included. The supplier's price list does not specify the suffix or finish for this reference.
Are the decibels in the technical sheet the noise I will hear at home?
Indoor sound pressure in cold: 33 / 36 / 40 dB(A). Outdoor sound pressure in cold: 54 dB(A) in cold. Maintain the indicated speed and mode when comparing. Sound pressure and sound power are different magnitudes; the perceived noise also depends on the room and the installation.
What should I check if I want to make use of my ducts?
To install PEAD-SM125JA + PUZ-SM125YKA, the technician must check the flow rate and condition of the network, the return grilles, the drainage, and the maintenance access. Just because the unit fits does not guarantee that the ducts will properly distribute its 12.1 kW of cooling. The price does not include adapting that network.
What does YKA provide compared to VKA in this pair?
It allows you to choose the three-phase variant intended for the installation. It does not add nominal capacity compared to PEAD-SM125JA + PUZ-SM125VKA: both publish 12.1 kW in cooling and 13.5 kW in heating.
When to switch from PEAD125 to PEAD140?
When the demand requires more than 12.1 kW in cooling from the PEAD125, the PEAD140 increases to 13.4 kW and its interior width changes from 1,400 to 1,600 mm; it's not just about changing a figure in the budget.
Can it be used in a venue with several rooms?
A duct network can distribute air between rooms if it is designed for their demands and flow rates. The system does not include an interior unit for each room or independent regulation by zone; that distribution and its control must be defined separately.
Can I set a different temperature in each room?
The supply includes a control for the assembly, not a room zoning system. To regulate zones independently, compatible controls and distribution elements are needed, defined separately according to the duct network.

Services for your air conditioning

Complete setCheck references and quantities.
Shipping includedMainland Spain · 24–48 h
Separate installationSpecific budget
DocumentationModel data and limits
Mitsubishi Electric ducted air conditioning PEAD-SM125JA + PUZ-SM125YKA