Mitsubishi Electric ducted air conditioning PEAD-SM125JA + PUZ-SM125YKA
Shipping included to mainland Spain · delivery in 24–48 h. Installation not included.
Mitsubishi Electric ducted air conditioning: PEAD-SM125JA + PUZ-SM125YKA. 1 × PEAD-SM125JA (indoor unit); 1 × PUZ-SM125YKA (outdoor unit); 1 × PAR-41 (remote control). Installation not included. The PEAD-SM125JA with PUZ-SM125YKA is the three-phase ducted pair with a nominal cooling capacity of 12.1 kW and heating capacity of 13.5 kW. Its indoor unit measures 250 × 1,400 × 732 mm; the space required for ducts, return, and maintenance must be checked in the project. Seasonal efficiency: cooling 210.6%; heating 150.1%. The Spanish catalog from June 2025, PDF 186, expresses these in percentage; they are not SEER/SCOP ratios nor converted into an invented energy class. The supplier's rate states that a PAR-41 remote control is included. The finish and extended name of the variant are not specified in that source. The published figures identify their sources; this document review does not verify the serial number or the physical content of the order.
What does PEAD-SM125JA + PUZ-SM125YKA include?
The composition identifies each reference and quantity. It does not replace the compatibility table for other combinations.
| Model | Component | Supply scope |
|---|---|---|
| PEAD-SM125JA | Indoor unit Ducted indoor unit | 1 included |
| PUZ-SM125YKA | Outdoor unit Outdoor unit of this 1×1 pair, three-phase power supply. | 1 included |
| PAR-41 | Control board PAR-41 remote included. The supplier's price list does not specify the suffix or finish for this reference. | 1 included |
Additional accessories not explicitly specified in the order Installation work and materials not explicitly budgeted
The images maintain the reference or family scope indicated in their description; they do not certify stock availability or the serial number that will be supplied.
What to check before installing PEAD-SM125JA + PUZ-SM125YKA
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Check the references PEAD-SM125JA + PUZ-SM125YKA and the revision of their labels before replacing units.
- Evaluate the thermal demand, distribution, insulation, and location before selecting ducted air conditioning.
- Check dimensions, clearances, power supply, and travel with the specific documentation and a qualified installer.
- The budget must separate equipment, materials, assembly, and commissioning.
Technical sheet: PEAD-SM125JA + PUZ-SM125YKA
- Brand
- Mitsubishi Electric
- Model and composition
- PEAD-SM125JA + PUZ-SM125YKA
- Supply scope
- 1 × PEAD-SM125JA (indoor unit); 1 × PUZ-SM125YKA (outdoor unit); 1 × PAR-41 (remote control)
- Installation
- Not included
- Availability and transport
- New equipment available. VAT and shipping included to mainland Spain · delivery in 24–48 h. Installation not included. Not shipped to islands, Ceuta, Melilla, or abroad.
Specifications and dimensions of the model
Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.
- Nominal power in cold conditions
- 12.1 kW
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. - Nominal heat output
- 13.5 kW
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. - Power supply / phase
- Three-phase
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. - Refrigerant
- R32
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications of PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. - Normalized annual consumption in cold
- 898 kWh/year
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · General catalog, June 2025 edition, PDF 186. Normalized test data of the pair; it does not predict the bill or the actual consumption of the home. - Normalized annual consumption in heat · average climate
- 3.085 kWh/year
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · General catalog, June 2025 edition, PDF 186. Normalized test data of the pair; it does not predict the bill or the actual consumption of the home. - Published seasonal efficiency in percentage
- Seasonal efficiency: cooling 210.6%; heating 150.1%.
Seasonal efficiency of this pair · Source: Mitsubishi Electric Spain · General catalog, June 2025 edition, PDF 186. The table in this edition publishes percentages: they are kept as percentages, without converting them into SEER/SCOP ratios. - Indoor unit · height × width × depth
- 250 × 1,400 × 732 mm
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Body dimensions, no mounting reserve; check protrusions, clearances and accessories in the plan. - Weight of the indoor unit
- 40 kg
Units bodies, acoustics, and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, document consulted on September 7, 2026, PDF 1. - Interior sound pressure in cold
- 33 / 36 / 40 dB(A)
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Values by fan speed; sound pressure, not sound power. - Outdoor unit · height × width × depth
- 981 × 1,050 × 330 mm
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Body dimensions, no mounting reserve; check protrusions, clearances and accessories in the plan. - Weight of the outdoor unit
- 85 kg
Units bodies, acoustics, and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, document consulted on September 7, 2026, PDF 1. - External sound pressure in cold conditions
- 54 dB(A) in cold
Units bodies, acoustics, and connectivity · Source: Mitsubishi Electric Spain · Technical specifications PEAD ducts, edition not indicated, copy consulted on September 7, 2026, PDF 1. Nominal value in cooling; not extrapolated to heating. - Nominal electrical power in cold conditions
- 4.17 kW
Electric power and operation at different loads · Electricity consumed under nominal testing conditions; it is not a constant consumption nor a data in kWh/year. - Nominal electric power in heat
- 3.85 kW
Electric power and operation at different loads · Electricity consumed under nominal conditions; it should not be confused with the thermal power delivered. - EER / nominal COP
- 2,9 / 3,5
Electric power and operation at different loads · Efficiency ratios under nominal conditions; they are not SEER/SCOP and do not guarantee that performance at any temperature. - Cold capacity range
- 6 to 13 kW
Electric power and operation at different loads · Minimum and maximum capacity published for this exact pair. It does not represent its electrical consumption. - Heating capacity range
- 4.1 to 15 kW
Electric power and operation at different loads · Minimum and maximum capacity from the catalog; it is not a covered area nor a constant power under any external conditions. - Design heat load at -10 °C (Pdesign)
- 8.5 kW
Electric power and operation at different loads · Design load for heating at the indicated reference temperature. This is a value different from the nominal capacity in heat. - Airflow of the indoor unit
- 29.5 / 35.5 / 42 m³/min
Airflow and available pressure · Values for low, medium, and high speed, in the order L/M/H from the manufacturer's table. - Selectable static pressure
- 35 / 50 / 70 / 100 / 150 Pa
Airflow and available pressure · Settings published by Mitsubishi; they do not guarantee the same airflow with any length or duct pressure loss. - Air flow of the outdoor unit
- 86 m³/min
Airflow and available pressure · Data from the outdoor unit, not ventilation or air renewal flow. - Supply voltage
- 400 V
Electrical and refrigeration connections · This pair is three-phase. Check the actual power supply before installation. - Maximum intensity of the set
- 14.3 A
Electrical and refrigeration connections · Value of the row Voltage/Phases - Maximum Current. This is not the rating of the circuit breaker: the line and protections must be sized for the installation. - Pipe diameters · liquid / gas
- 9.52 / 15.88 mm
Electrical and refrigeration connections · Liquid/gas order from the catalog. Check materials, insulation, connections, and exact review in the installation manual. - Maximum pipe slope
- 30 m
Electrical and refrigeration connections · Published vertical limit for the pair; also check the layout and restrictions in the manual. - Maximum total pipe length
- 40 m
Electrical and refrigeration connections · Actual pipe run, not straight-line distance. These are not meters included in the purchase nor a confirmation that the pre-charge covers the entire run. - Factory refrigerant pre-charge
- 3.6 kg of R32
Electrical and refrigeration connections · Factory quantity published by Mitsubishi. The additional load depends on the run and the manual of the outdoor unit; it is not calculated here by assumption. - Cold operation outdoor range
- -15 to 46 °C
Installation and operating limits · For cooling with an outdoor environment below -5 °C, the catalog requires an optional wind protection guide. The range does not guarantee nominal power at all points. - Operating temperature range for heating
- -15 to 21 °C
Installation and operating limits · Published outdoor operating temperatures; they do not equate to a guarantee of nominal capacity across the entire range. - Nominal pipe length of the test
- 5 m
Installation and operating limits · Length used by the manufacturer to calculate capacity under nominal conditions; it is not pipe supplied with the assembly. - Maximum number of curves
- 15
Installation and operating limits · Limit indicated in the catalog notes. It should be reviewed along with the length, the elevation difference, and the installation manual. - Dehumidification limit
- It does not work below 13 °C in the room.
Installation and operating limits · Condition expressly stated by Mitsubishi in the notes of this series; do not confuse it with the outdoor operating range. - Drain pump
- Incorporated
Installation and operating limits · Performance indicated on the page of this series. The drainage pipe, its execution, and the permissible height are reviewed during installation. - Condensate control
- Incorporated
Installation and operating limits · The catalog indicates that it is incorporated in the units. It does not replace the wind protection required for certain uses in cold conditions. - Additional indication for exterior background
- (+40) mm according to the catalog
Installation and operating limits · The table shows the overall dimension as 981 × 1,050 × 330 (+40) mm. Complete the previously published body measurements; it is not a maintenance clearance nor is it attributed to a specific part without a drawing. - Remote control included
- PAR-41 remote included. The supplier's price list does not specify the suffix or finish for this reference.
Remote control and connectivity - Wi-Fi
- Wi-Fi is not included in this offer. Mobile control requires a compatible accessory; its reference must be verified for the specific equipment.
Remote control and connectivity
- The unit, condition, and source of each value from the original catalog are preserved. The indicated editions and revisions define their scope; missing figures are not completed by analogy. Uniclima's commercial conditions are validated separately.
Manuals and technical documentation
Official sources from the manufacturer. Cross-check the model and the revision of the labels of both units.
- Mitsubishi Electric Spain · PEAD PRO Series (Web)Documented scope: Indoor unit · height × width × depth; Weight of the indoor unit; Sound pressure level indoors in cooling; Weight of the outdoor unit; Sound pressure level outdoors in cooling
- Mitsubishi Electric · General catalog June 2025 (PDF)Documented scope: Normalized annual consumption in cold; Normalized annual consumption in heat · average climate; Published seasonal efficiency in percentage
- Mitsubishi Electric · General catalog, June 2025 · printed page 184 · PDF 186 (PDF)Documented scope: Cold operation outdoor range; Hot operation outdoor range; Nominal test pipe length; Maximum number of bends; Dehumidification limit; Drain pump; Condensation control; Additional indication of outdoor background.
Questions about PEAD-SM125JA + PUZ-SM125YKA
What is included in PEAD-SM125JA + PUZ-SM125YKA?
What measurements should I check before booking the equipment?
How much electricity does it need and how is it distinguished from cooling power?
Is Wi-Fi included or is an accessory required?
What command does the equipment receive?
Are the decibels in the technical sheet the noise I will hear at home?
What should I check if I want to make use of my ducts?
What does YKA provide compared to VKA in this pair?
When to switch from PEAD125 to PEAD140?
Can it be used in a venue with several rooms?
Can I set a different temperature in each room?
Services for your air conditioning
- Installation
- Check location, route, and commissioning.
- Maintenance
- Check the operations for your equipment.