Representación ilustrativa Split 1×1: MSZ-HR25VFK + MUZ-HR25VF. Capacidad en frío: 2.5 kW, aproximadamente 2150 frigorías por hora. Capacidad en calor: 3.15 kW. Eficiencia en frío A++. Consumo anual normalizado en frío: 141 kWh. Render basado en fotografías de referencia; originales en la galería, no a escala.

Mitsubishi Electric MSZ-HR25VFK + MUZ-HR25VF split wall-mounted air conditioning unit 1×1.

Shipping included to mainland Spain · delivery in 24–48 h. Installation not included.

VAT includedAvailable · delivery in 24–48 h

Mitsubishi Electric split wall-mounted unit 1×1: MSZ-HR25VFK + MUZ-HR25VF. 1 × MSZ-HR25VFK (indoor unit); 1 × MUZ-HR25VF (outdoor unit); 1 × RH18A (remote control). Installation not included. The HR25VFK features integrated Wi-Fi in the indoor unit and is paired with the MUZ-HR25VF. Its SCOP of 4.3 is linked to the Spanish catalog from June 2025 and to the ErP information M-172 for this pair. For MSZ-HR25VFK + MUZ-HR25VF, the sources indicated in the table document a SEER of 6.2 and a SCOP of 4.3 in moderate climate. These are normalized data for the set, not a constant performance or a promise of expenditure in any installation. Includes 1 infrared remote control: 1 × RH18A. The published figures identify their sources; this document review does not verify the serial number or the physical content of the order.

Components and supply

What is included in MSZ-HR25VFK + MUZ-HR25VF?

The composition identifies each reference and quantity. It does not replace the compatibility table for other combinations.

ModelComponentSupply scope
MSZ-HR25VFKIndoor unit
Wall-mounted indoor unit with integrated Wi-Fi
1 included
MUZ-HR25VFOutdoor unit
Outdoor unit of this 1×1 pair, single-phase power supply.
1 included
RH18AControl board
Includes 1 remote control: 1 × RH18A.
1 included

Additional accessories not explicitly specified in the order Installation work and materials not explicitly budgeted

The images maintain the reference or family scope indicated in their description; they do not certify stock availability or the serial number that will be supplied.

Guide

What to check before installing MSZ-HR25VFK + MUZ-HR25VF

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Check the references MSZ-HR25VFK + MUZ-HR25VF and review their labels before replacing units.
  2. Evaluate the thermal demand, distribution, insulation, and location before selecting a 1×1 wall-mounted split.
  3. Check dimensions, clearances, power supply, and travel with the specific documentation and a qualified installer.
  4. The budget must separate equipment, materials, assembly, and commissioning.
Technical data

MSZ-HR25VFK + MUZ-HR25VF

Brand
Mitsubishi Electric
Model and composition
MSZ-HR25VFK + MUZ-HR25VF
Supply scope
1 × MSZ-HR25VFK (indoor unit); 1 × MUZ-HR25VF (outdoor unit); 1 × RH18A (remote control)
Installation
Not included
Availability and transport
New equipment available. VAT and shipping included to mainland Spain · delivery in 24–48 h. Installation not included. Not shipped to islands, Ceuta, Melilla, or abroad.

Specifications and dimensions of the model

Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.

Nominal power in cold conditions
2.5 kW
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Nominal heat output
3.15 kW
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Power supply / phase
Single-phase
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Refrigerant
R32
Couple and documented nominal ratings · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1.
SEER of the set
6,2
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, document consulted on September 7, 2026, PDF 1.
Energy class in cold
A++
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, document consulted on September 7, 2026, PDF 1.
Energy class in heating · average climate
A+
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, document consulted on September 7, 2026, PDF 1.
Normalized annual consumption in cold
141 kWh/year
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1. Normalized test data of the pair; does not predict the bill or the actual consumption of the home.
Normalized annual consumption in heat · average climate
614 kWh/year
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1. Normalized test data of the pair; does not predict the bill or the actual consumption of the home.
SCOP of the set · average climate
4,3
Seasonal performance of this pair · Source: Mitsubishi Electric Spain · General catalog, edition June 2025, PDF 153; Mitsubishi Electric · ErP Information M-172, pair HR25 VF/VFK + MUZ-HR25VF, PDF 4.
Indoor unit · height × width × depth
280 × 838 × 228 mm
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1. Body dimensions, no mounting reserve; check protrusions, clearances and accessories in the plan.
Weight of the indoor unit
8.5 kg
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1.
Interior sound pressure in cold
21 / 30 / 37 / 43 dB(A)
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1. Values by fan speed; sound pressure, not sound power.
Outdoor unit · height × width × depth
538 × 699 × 249 mm
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1. Body dimensions, no mounting reserve; check protrusions, clearances and accessories in the plan.
Weight of the outdoor unit
23 kg
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1.
External sound pressure in cold conditions
50 dB(A)
Units bodies, acoustics and connectivity · Source: Mitsubishi Electric Spain · Technical specifications MSZ-HR VFK, edition not indicated, copy consulted on September 7, 2026, PDF 1. Nominal value in cooling; not extrapolated to heating.
Indoor air flow in cold · low / medium / high / super high
216 / 324 / 432 / 582 m³/h
Ventilation and acoustics of the indoor unit · Sound flow/pressure at indoor speeds, does not include acoustic sum or performance of the multisplit. OBH822H: ISO 5151; indoor cooling 27 °C BS/19 °C BH and outdoor 35 °C BS; indoor heating 20 °C BS and outdoor 7 °C BS/6 °C BH.
Indoor air flow in heating · low / medium / high / super high
198 / 324 / 444 / 606 m³/h
Ventilation and acoustics of the indoor unit · Sound flow/pressure at indoor speeds, does not include acoustic sum or performance of the multisplit. OBH822H: ISO 5151; indoor cooling 27 °C BS/19 °C BH and outdoor 35 °C BS; indoor heating 20 °C BS and outdoor 7 °C BS/6 °C BH.
Interior sound pressure in heating · low / medium / high / super high
21 / 30 / 37 / 43 dB(A)
Ventilation and acoustics of the indoor unit · Sound flow/pressure at indoor speeds, does not include acoustic sum or performance of the multisplit. OBH822H: ISO 5151; indoor cooling 27 °C BS/19 °C BH and outdoor 35 °C BS; indoor heating 20 °C BS and outdoor 7 °C BS/6 °C BH.
Cold power range · minimum / maximum
0.5 / 2.9 kW
Ranges and nominal consumption of the pair · Nominal data of the exact pair from the official table cited; no constant consumption, annual or expenditure in euros. Do not transfer to MXZ combinations.
Power range in heating · minimum / maximum
0.5 / 3.5 kW
Ranges and nominal consumption of the pair · Nominal data of the exact pair from the official table cited; no constant consumption, annual or expenditure in euros. Do not transfer to MXZ combinations.
Nominal electrical power in cold conditions
0.8 kW
Ranges and nominal consumption of the pair · Nominal data of the exact pair from the official table cited; no constant consumption, annual or expenditure in euros. Do not transfer to MXZ combinations.
Nominal electric power in heat
0.85 kW
Ranges and nominal consumption of the pair · Nominal data of the exact pair from the official table cited; no constant consumption, annual or expenditure in euros. Do not transfer to MXZ combinations.
nominal EER
3,13
Ranges and nominal consumption of the pair · Nominal data of the exact pair from the official table cited; no constant consumption, annual or expenditure in euros. Do not transfer to MXZ combinations.
nominal COP
3,71
Ranges and nominal consumption of the pair · Nominal data of the exact pair from the official table cited; no constant consumption, annual or expenditure in euros. Do not transfer to MXZ combinations.
R32 pre-charge of the outdoor unit
0.4 kg
Operating limits and documented connections · Factory pre-charge of the outdoor unit MUZ-HR25VF in the cited VFK edition; no final charge calculated for an installation.
Connection diameter · liquid / gas
6.35 / 9.52 mm
Operating limits and documented connections · Connections of the exact pair. The actual length and insulation must be sized during installation.
Pipe limits · height difference / length
12 / 20 m
Operating limits and documented connections · Explicit order of height difference/length of the HR-VFK table. These are limits, not including piping.
Cold operating outdoor temperature
-10 / 46 °C
Operating limits and documented connections · Declared range; does not guarantee nominal power at its extremes.
Operating outdoor temperature in heating mode
-10 / 24 °C
Operating limits and documented connections · Declared range; does not guarantee nominal power at its extremes.
Remote control included
Includes 1 remote control: 1 × RH18A.
Remote control and connectivity
Wi-Fi
Integrated Wi-Fi in the indoor unit, with control via MELCloud. No additional adapter purchase is required. The remote control operates via infrared; the Wi-Fi is built into the unit.
Remote control and connectivity
Before purchasing
  • The unit, condition, and source of each value from the original catalog are preserved. The indicated editions and revisions define their scope; missing figures are not completed by analogy. Uniclima's commercial conditions are validated separately.
Documentation

Manuals and technical documentation

Official sources from the manufacturer. Cross-check the model and the revision of the labels of both units.

Frequently Asked Questions

Questions about MSZ-HR25VFK + MUZ-HR25VF

What does MSZ-HR25VFK + MUZ-HR25VF include?
1 × MSZ-HR25VFK (indoor unit); 1 × MUZ-HR25VF (outdoor unit); 1 × RH18A (remote control). The previous composition identifies the units and controls of this offer. The installation is contracted separately.
What measurements should I check before booking the equipment?
Indoor unit · height × width × depth: 280 × 838 × 228 mm. Outdoor unit · height × width × depth: 538 × 699 × 249 mm. These are the dimensions of the indicated components, not the minimum installation space. Also allow for the clearances, connections, and maintenance access required by the manual.
How much electricity does it need and how is it distinguished from cooling power?
Nominal electrical power in cold: 0.8 kW. Nominal electrical power in heat: 0.85 kW. Thermal power describes the cold or heat delivered; electrical power is the input to the equipment. The nominal values are not a constant consumption or a forecast of the bill.
What efficiency does this combination have and what can I compare?
SEER of the unit: 6.2. Energy class in cooling: A++. Energy class in heating · average climate: A+. SCOP of the unit · average climate: 4.3. Compare the same magnitude, combination, and test climate. This data does not certify the consumption of your home or the performance of another combination.
Is Wi-Fi included or is an accessory required?
Integrated Wi-Fi in the indoor unit, with control via MELCloud. No additional adapter purchase is required. The remote control operates via infrared; the Wi-Fi is built into the unit.
What command does the equipment receive?
Includes 1 remote control: 1 × RH18A.
Are the decibels in the technical sheet the noise I will hear at home?
Indoor sound pressure in cold: 21 / 30 / 37 / 43 dB(A). Outdoor sound pressure in cold: 50 dB(A). Indoor sound pressure in heat · low / medium / high / super high: 21 / 30 / 37 / 43 dB(A). Maintain the indicated speed and mode when comparing. Sound pressure and sound power are different magnitudes; perceived noise also depends on the room and the installation.
What does the K offer compared to the HR25VF?
In this variant, HR25VFK incorporates Wi-Fi while HR25VF offers it as a separate option. The outdoor unit MUZ-HR25VF and the nominal capacity of 2.5 kW in cooling remain unchanged; you are not buying more power by adding the K.
Can it fit in a bedroom for nighttime use?
It can be an option if the bedroom demand corresponds to 2.5 kW. The indoor noise level starts at 21 dB(A) at low speed and increases with the fan; the location relative to the bed also matters for comfort.
Should I choose HR25VFK or HR35VFK?
HR25VFK offers 2.5 kW nominal in cooling and HR35VFK, 3.4 kW. Both include Wi-Fi and remote control; choose according to the needs of the room, without expecting that the HR35 will serve two rooms just because it has a higher capacity.

Services for your air conditioning

Complete setCheck references and quantities.
Shipping includedMainland Spain · 24–48 h
Separate installationSpecific budget
DocumentationModel data and limits