Mitsubishi Electric MSZ-HR42VFK 1x1 air conditioning — 4.2 kW
Are you looking for a unit of about 3,500 frigorías? This set offers 3,612 nominal frigorías/h.
Shipping included to mainland Spain. Installation not included.
1×1 split wall-mounted set with indoor unit MSZ-HR42VFK, outdoor unit MUZ-HR42VF, and remote control RH18A. It offers 4.2 kW nominal cooling and 4.7 kW heating, with integrated Wi-Fi and control via MELCloud. New equipment; installation not included. The Mitsubishi Electric HR42VFK is an air conditioning and heat pump set designed to climate a room. It combines the wall unit MSZ-HR42VFK with the outdoor unit MUZ-HR42VF; it is not a standalone indoor unit or a multisplit system for two independent rooms. In cooling mode, it declares 4.2 kW nominal, equivalent to 3,612 frigorías/h, with a seasonal classification of A++. In heating mode, it delivers 4.7 kW nominal and reaches A+ in moderate climate. The capacity adapts within the ranges indicated in the technical sheet; sizing must consider insulation, orientation, occupancy, and solar gains. You can operate it with the included infrared remote control RH18A or connect the integrated Wi-Fi interface to MELCloud. Remote connection requires a compatible network and service configuration; no external Wi-Fi adapter is needed for this VFK version. The price corresponds to the supply of the set and includes VAT and shipping to mainland Spain, with delivery in 24–48 hours. It is not shipped to the Balearic Islands, Canary Islands, Ceuta, Melilla, or abroad. Installation, pipes, supports, and construction materials are not included; assembly is quoted separately.
What does the Mitsubishi Electric HR42VFK include?
Split pair 1×1: one indoor unit, one outdoor unit, and its remote control. It does not confirm combinations with other units or multisplit systems.
| Model | Component | Supply scope |
|---|---|---|
| MSZ-HR42VFK | Indoor unit White wall-mounted · Integrated Wi-Fi · 838 mm wide | Included |
| MUZ-HR42VF | Outdoor unit Heat pump · refrigerant R32 · 34 kg | Included |
| RH18A | Remote control included An infrared remote control for the set | Included |
Installation, pipes, supports, and construction materials not included. The overall image is illustrative, not a scale photograph. What to check before installation.
What to check before installing the HR42VFK
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Identify the complete pair: MSZ-HR42VFK and MUZ-HR42VF. Also, compare the label review with the documentation; the name HR42 alone does not describe all versions.
- Dimension the room with a professional: surface area and height, orientation, insulation, glazing, occupancy, and use. Do not choose solely based on cooling capacity or square meters.
- Check where both units, the drainage and the refrigerant line, will go. The published limit is 20 m of piping and 12 m of elevation; these lengths are not included in the supply.
- Confirm power supply, protections, outdoor ventilation, supports, and accessibility. The installation and handling of the refrigeration circuit must be carried out by qualified personnel.
- Request a quote that separates equipment, materials, installation, and commissioning. The supply includes mainland shipping within 24–48 hours; confirm with the installer the necessary accessories for your home.
Operation and alerts of the HR42VFK
What to observe and when to request a review
- 01
The compressor does not restart immediately.
Por favor, proporciona el texto que deseas traducir. The manual includes a protection period of approximately three minutes after stopping the compressor. A delayed start does not confirm a fault on its own.
Wait for that interval without chaining on and off cycles. If the malfunction persists, note the mode, the setpoint, and the lights on the unit.
- 02
It does not respond to the infrared remote control.
Por favor, proporciona el texto que deseas traducir. The state of the batteries or the reception of the signal can affect the control. This does not automatically identify a fault in the PCB.
Check the batteries and try with the remote aimed at the receiver, without obstacles. Do not open the electrical components.
- 03
MELCloud does not connect, but the remote control works.
Por favor, proporciona el texto que deseas traducir. Internet control depends on the network, the interface configuration, and the MELCloud service; it is different from infrared control.
Check the router connection and the configuration indicated in the Wi-Fi manual. Do not replace components based solely on a connection fault.
- 04
The operation indicator is flashing.
Por favor, proporciona el texto que deseas traducir. The service manual interprets flashing sequences according to the model and revision. A code taken from another family may lead to an incorrect diagnosis.
Record the sequence, behavior, and complete references. Provide this data to the technical service; do not access the refrigeration circuit or the electronics.
A warning does not identify a faulty part by itself. Record the references of both units and the signaling; do not open the electronics or manipulate the refrigeration circuit.
Mitsubishi Electric HR42VFK
- Brand
- Mitsubishi Electric
- Set
- MSZ-HR42VFK + MUZ-HR42VF
- Status
- New
- Supply scope
- Indoor unit, outdoor unit, and RH18A control.
- Installation
- Not included
- Availability and transport
- Shipping included to mainland Spain · delivery in 24–48 hours. Not shipped to islands, Ceuta, Melilla, or abroad.
Specifications and dimensions of the model
Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.
- Brand
- Mitsubishi Electric
Identification and supply - Type
- 1×1 wall-mounted split with heat pump
Identification and supply - Indoor unit
- MSZ-HR42VFK
Identification and supply - Outdoor unit
- MUZ-HR42VF
Identification and supply - Equipment condition
- New
Identification and supply - Remote control included
- RH18A · 1 unit
Identification and supply - Connectivity
- Integrated Wi-Fi · MELCloud
Identification and supply - Power supply
- 230 V · 50 Hz · single-phase
Identification and supply - Maximum published intensity
- 8.5 A
Identification and supply - Nominal cooling (min.–max.)
- 4.2 kW (1.1–4.5 kW)
Capacity and absorbed power - Equivalent nominal cooling
- 3,612 frigorías/h
Capacity and absorbed power - Nominal heating (min.–max.)
- 4.7 kW (0.9–5.4 kW)
Capacity and absorbed power - Equivalent nominal heating
- 4,042 kcal/h
Capacity and absorbed power - Nominal electrical power in cold conditions
- 1.34 kW
Capacity and absorbed power - Nominal electric power in heat
- 1.30 kW
Capacity and absorbed power - nominal EER / COP
- 3,13 / 3,62
Capacity and absorbed power - SEER / cooling class
- 6.5 / A++
Seasonal efficiency - SCOP / class in heating, medium climate
- 4.3 / A+
Seasonal efficiency - SCOP / class in heating, warm climate
- 5.2 / A+++
Seasonal efficiency - Normalized annual consumption in cold
- 226 kWh/year
Seasonal efficiency - Normalized annual consumption in heat, average climate
- 928 kWh/year
Seasonal efficiency - Normalized annual consumption in heat, warm climate
- 427 kWh/year
Seasonal efficiency - Dimensions (height × width × depth)
- 280 × 838 × 228 mm
Indoor unit: size, air, and noise - Net weight
- 9 kg
Indoor unit: size, air, and noise - Fan speeds
- 4
Indoor unit: size, air, and noise - Cold air flow
- 360 / 522 / 648 / 786 m³/h
Indoor unit: size, air, and noise - Airflow in heating
- 336 / 474 / 648 / 804 m³/h
Indoor unit: size, air, and noise - Sound pressure in cold
- 24 / 34 / 39 / 45 dB(A)
Indoor unit: size, air, and noise - Sound pressure in heating
- 24 / 32 / 40 / 46 dB(A)
Indoor unit: size, air, and noise - Declared sound power
- 60 dB(A)
Indoor unit: size, air, and noise - Dimensions (height × width × depth)
- 550 × 800 × 285 mm
Outdoor unit: size, air, and noise - Net weight
- 34 kg
Outdoor unit: size, air, and noise - Published air flow
- 34.3 m³/min
Outdoor unit: size, air, and noise - Published sound pressure
- 50 dB(A)
Outdoor unit: size, air, and noise - Declared sound power
- 64 dB(A)
Outdoor unit: size, air, and noise - Refrigerant
- R32
Refrigeration circuit and installation limits - Factory load
- 0.70 kg
Refrigeration circuit and installation limits - Global warming potential (GWP)
- 675
Refrigeration circuit and installation limits - Equivalent of CO₂ of the published load
- 0.47 tons
Refrigeration circuit and installation limits - Diameter of liquid/gas pipe
- 6.35 / 9.52 mm (1/4 / 3/8 inches)
Refrigeration circuit and installation limits - Maximum pipe length
- 20 m
Refrigeration circuit and installation limits - Maximum slope
- 12 m
Refrigeration circuit and installation limits - Cold operating outdoor temperature
- −10 to +46 °C
Refrigeration circuit and installation limits - Operating outdoor temperature in heating mode
- −10 to +24 °C
Refrigeration circuit and installation limits
- The values of flow rate and indoor sound pressure follow the order of low, medium, high, and super high. Sound pressure and sound power are distinct magnitudes. Nominal capacities and consumptions correspond to tests; annual consumptions are standardized and are not a forecast of the bill. In the service documentation, the cold test uses 27 °C indoor (dry bulb) and 35 °C outdoor; for heating, 20 °C indoor and 7 °C outdoor. Operating within an outdoor range does not imply maintaining nominal capacity at all its extremes.
Manuals and technical documentation
Official sources from the manufacturer. Cross-check the model and the revision of the labels of both units.
- MSZ-HR VFK (PDF)Mitsubishi Electric Spain · capacities, efficiency, noise, dimensions, and installation limits.
- Service manual OBH822H (PDF)Official library of Mitsubishi Electric · includes MSZ-HR42VFK; check your equipment's revision. Technical document in English.
Questions about the Mitsubishi Electric HR42VFK
What does the Mitsubishi Electric HR42VFK set include?
Does the HR42VFK have Wi-Fi or do you need to buy an adapter?
How many frigorías does it have and what power does it offer for heating?
How many square meters is the Mitsubishi HR42 suitable for?
What is the difference between HR35, HR42, and HR50?
Can it air condition two rooms independently?
Can I buy just the split and connect it to another outdoor unit?
How much does the HR42VFK consume and how much will it cost to use it?
Why do A++, A+, and A+++ appear on the same sheet?
Can it be used for heating during the winter?
What noise does the indoor unit of the HR42 make?
How much space do I need to install the units?
Does it include installation, pipes, or supports?
What length of pipe does it accommodate and what diameters does it use?
What refrigerant does it use and what is the factory charge?
Is it normal for it to take time to start after turning it off?
What information should I provide if the light is flashing or stops working?
Where can I check the data and instructions for the equipment?
Services for your air conditioning
- Installation
- Check location, route, and commissioning.
- Maintenance
- Check the operations for your equipment.