Multisplit air conditioning 2×1 Panasonic CU-2TZ50TBE + CS-TZ25ZKEW + CS-TZ35ZKEW — 4,300 FRIGORÍAS/h
Panasonic CU-2TZ50TBE + CS-TZ25ZKEW + CS-TZ35ZKEW set: 5.00 kW cooling, 5.70 kW heating, and approximately 4,300 BTU/h of shared capacity. R32. Integrated Wi-Fi and wireless remote control in each indoor unit.
- Pipe
- 1/4″ / 3/8″
- Wi-Fi
- Yes, included.
- BTU/h
- ≈ 4.300
- Refrigerant
- R32
VAT included. Installation not included.
What is included in Panasonic CU-2TZ50TBE + CS-TZ25ZKEW + CS-TZ35ZKEW?
Composition of the set: CS-TZ25ZKEW + CS-TZ35ZKEW + CU-2TZ50TBE.
| Model | Component | Supply scope |
|---|---|---|
| CS-TZ25ZKEW | Wall-mounted indoor unit 779 × 290 × 209 mm | 1 included |
| CS-TZ35ZKEW | Wall-mounted indoor unit 779 × 290 × 209 mm | 1 included |
| CU-2TZ50TBE | Multisplit outdoor unit 780 × 542 × 289 mm | 1 included |
| Panasonic TZ wireless remote control | Wireless remote control from the range The design may vary due to catalog updates. | 2 included |
Installation, pipes, supports, and construction materials not included. The power is shared between the indoor units.
Illustration of the range based on images from the manufacturer; not to scale. The design of the control may vary due to catalog updates.
What to check before installing Panasonic CU-2TZ50TBE + CS-TZ25ZKEW + CS-TZ35ZKEW
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Size the power according to the thermal load of each space.
- Respect the manufacturer's maintenance, ventilation, and drainage spaces.
- Check the single-phase power supply, the 1/4″ / 3/8″ pipes, and the allowable lengths.
- The external power is distributed among the interiors. The system operates in either heating or cooling mode; not in both modes at the same time.
Technical sheet: Panasonic CU-2TZ50TBE + CS-TZ25ZKEW + CS-TZ35ZKEW
- Brand
- Panasonic
- Model and composition
- Panasonic CU-2TZ50TBE + CS-TZ25ZKEW + CS-TZ35ZKEW
- Supply scope
- 1 × CU-2TZ50TBE; CS-TZ25ZKEW + CS-TZ35ZKEW; 2 wireless remote(s).
- Installation
- Not included
- Availability and transport
- Price including VAT. Installation not included. Request the availability notice if it is out of stock.
Installation at a glance
- Pipe · liquid / gas
- 1/4″ / 3/8″By interior
- Length covered by precharge
- 20 mTotal
- Additional load
- 15 g/mAccording to length and manual
- Maximum slope
- 10 mBetween interior and exterior; the separated values depend on the relative position of the units.
Specifications and dimensions of the model
Capabilities, consumption, efficiency, noise, and dimensions of this set. The testing conditions and climate are part of each value.
- Nominal cooling of the unit
- 5.00 kW
Power and efficiency of the system · Shared between rooms - Nominal heat of the assembly
- 5.70 kW
Power and efficiency of the system · Shared between rooms - BTU/h
- ≈ 4.300
Power and efficiency of the set · Nominal cooling of the set × 860 - Nominal power in cooling / heating
- 1.30 / 1.31 kW
Power and efficiency of the system - SEER / SCOP
- 7,00 / 4,20
Power and efficiency of the system · SCOP in moderate climate; selector values for this combination - Energy class in cold
- A++
Power and efficiency of the system - Interior 1 · CS-TZ25ZKEW
- 2.10 kW cooling / 2.35 kW heating
Power and efficiency of the set · Nominal distribution of this combination - Interior 2 · CS-TZ35ZKEW
- 2.90 kW cooling / 3.35 kW heating
Power and efficiency of the set · Nominal distribution of this combination - CS-TZ25ZKEW · width × height × depth
- 779 × 290 × 209 mm
Dimensions and sound · 1 unit(s) - CS-TZ35ZKEW · width × height × depth
- 779 × 290 × 209 mm
Dimensions and sound · 1 unit(s) - CU-2TZ50TBE
- 780 × 542 × 289 mm
Dimensions and sound · Width × height × depth - Interior sound pressure CS-TZ25ZKEW
- 40 / 26 / 20 dB(A)
Measurements and sound · Cold: high / low / quiet - Interior sound pressure CS-TZ35ZKEW
- 42 / 30 / 20 dB(A)
Measurements and sound · Cold: high / low / quiet - Refrigerant
- R32
Installation and refrigerant - Factory load
- 0.90 kg
Installation and refrigerant - Pipe · liquid / gas
- 1/4″ / 3/8″
Installation and refrigerant · For indoor use - Length covered by precharge
- 20 m
Installation and refrigerant · Total - Additional load
- 15 g/m
Installation and refrigerant · According to length and manual - Maximum total length
- 30 m
Installation and refrigerant - Maximum slope
- 10 m
Installation and refrigerant · Between interior and exterior; the separated values depend on the relative position of the units. - External power supply
- Single-phase · 220–230–240 V · 50 Hz
Installation and refrigerant - Wi-Fi
- Included · Comfort Cloud
Installation and refrigerant - Control board
- Panasonic TZ wireless remote control
Installation and refrigerant · 2 included - Panasonic Spain warranty
- 3 years
Installation and refrigerant · According to the manufacturer's warranty conditions, linked in Documentation - Maximum length per branch
- 20 m
Installation and refrigerant - Number of rooms
- 2
Installation and refrigerant · One indoor unit per room
- The testing conditions and installation instructions are detailed in the Panasonic documentation. The indicated capacity is shared among the indoor units.