TCL cassette set: illustration of the range, not to scale

TCL cassette air conditioning M42S1S2 · 12.10 kW

1.558,83 €VAT included

10,406 frigorías/h from the ceiling, with a 950 × 950 mm panel included. Single-phase.

3/8″ / 5/8″ · Monofásica · body 245 mm de alto · precarga 5 m What to consider

VAT and shipping included. Installation not included. Availability and delivery time to be confirmed.

Availability to be confirmed
Components and supply

What does TCL M42S1S2 include?

Cassette Set 1×1: components grouped according to the TCL table.

ModelComponentSupply scope
MN42SS2Cassette indoor unit
26.0 kg
1 included
MT4212Outdoor unit
910 × 804 × 378 mm · 55 kg
1 included
NPAN90S1Cassette panel
950 × 950 × 45 mm
1 included

The reference and supply of the control unit are confirmed in the quote. Installation, piping, supports, wiring, and commissioning are budgeted separately.

Cover: illustrative composition of the range, not to scale. The official photographs of the indoor unit are shared among capacities. Check the references and dimensions of this set.

Guide

What to check before installing TCL M42S1S2

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Check the cassette body and the NPAN90S1 panel separately. The dimensions of the panel do not match the ceiling cutout; ensure access to drainage and maintenance.
  2. Tubería 3/8″ / 5/8″. Precarga para 5 m; longitud máxima equivalente 75 m y desnivel 30 m. Por encima de 5 m: 25 g/m adicionales. El instalador debe contrastar placa y revisión antes de intervenir.
  3. The set is single-phase. The installer will check the voltage of the PCB, the protections, the wiring, and the ventilation distances.
  4. The reference and the supply of the control are confirmed in the budget.
Technical data

TCL M42S1S2

Brand
TCL
Model and composition
TCL M42S1S2
Supply scope
MN42SS2 + MT4212 + NPAN90S1
Installation
Not included
Availability and transport
VAT and shipping included. Installation not included. Confirm availability and delivery time.

Specifications and dimensions of the model

Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.

Set
M42S1S2
Set and power supply
Indoor unit
MN42SS2
Set and power supply
Outdoor unit
MT4212
Set and power supply
Type
1×1 cassette · cooling and heating
Set and power supply
Power supply
220 V · single-phase
Set and power supply
Nominal power in cold conditions
12.10 kW
Power and efficiency
Approximate nominal cooling capacity
10,406 refrigeration units/h
Power and efficiency · Conversion: kW × 860.
Nominal heat output
13.50 kW
Power and efficiency
Energy class in cold
A++
Power and efficiency
Energy class in heating
A+
Power and efficiency
Body · published dimensions
840 × 840 × 245 mm
Measures to prepare the installation · Body without panel; confirm dimensions and space in the installation plan.
Exterior · width × height × depth
910 × 804 × 378 mm
Measures to prepare the installation
Net internal weight
26.0 kg
Measures to prepare the installation
Net external weight
55 kg
Measures to prepare the installation
Panel
NPAN90S1
Measures to prepare the installation
Panel · published dimensions
950 × 950 × 45 mm
Measures to prepare the installation
Pipe · liquid / gas
3/8″ / 5/8″
Pipe and refrigerant
Refrigerant
R32
Pipe and refrigerant
Factory published load
2.20 kg
Pipe and refrigerant · Catalog data; check the revision plate provided.
SEER
6,1
Eficiencia, consumo y circulación de aire
SCOP · average climate
4
Eficiencia, consumo y circulación de aire
Consumo nominal en frío
4240 W
Eficiencia, consumo y circulación de aire · Potencia eléctrica nominal, no capacidad térmica.
Consumo nominal en calor
3700 W
Eficiencia, consumo y circulación de aire · Potencia eléctrica nominal, no capacidad térmica.
External sound power
68 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora.
Potencia sonora interior · S/H/M/L/silencio
64/61/60/58/54 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora.
Caudal de aire interior
2100 m³/h
Eficiencia, consumo y circulación de aire
Tubería cubierta por la precarga
5 m
Límites para preparar la instalación · Catálogo TCL 2026 Portugal, página PDF 12; no es el recorrido máximo.
Longitud máxima equivalente
75 m
Límites para preparar la instalación · Catálogo oficial TCL Italia 2026, página PDF 59. Longitud equivalente, no solo tubo recto.
Maximum slope
30 m
Límites para preparar la instalación · Entre las unidades interior y exterior.
Longitud mínima recomendada
3 m
Límites para preparar la instalación · Catálogo oficial TCL Italia 2026.
Carga adicional por encima de 5 m
25 g/m
Límites para preparar la instalación · Dentro de los límites permitidos. Confirmar placa y revisión; intervención de profesional habilitado.
Before purchasing
  • Datos de la documentación enlazada para la referencia indicada. Verifica la placa y el manual de instalación de la revisión suministrada antes de dimensionar huecos, conexiones o carga de refrigerante. Las imágenes no son planos de montaje. Algunas cotas, pesos o cargas difieren entre el catálogo 2025–2026 y la ficha TCL actual. Confirma la revisión y su plano antes de preparar la instalación.

Documentation

Frequently Asked Questions

Questions about TCL M42S1S2

How many frigorías does the TCL M42S1S2 have?
Approximately 10.406 frigorías/h, starting from 12.10 kW nominal in cooling. This is thermal capacity, not electrical consumption.
What does the set include?
Indoor unit cassette MN42SS2, outdoor unit MT4212, cassette panel NPAN90S1. The reference and supply of the remote control are confirmed in the quote.
What pipe do you need?
Tubería 3/8″ / 5/8″. Precarga para 5 m; longitud máxima equivalente 75 m y desnivel 30 m. Por encima de 5 m: 25 g/m adicionales. El instalador debe contrastar placa y revisión antes de intervenir.
Are the dimensions of the panel the ceiling opening?
No. The NPAN90S1 panel measures 950 × 950 × 45 mm, but the opening and the clearances are taken from the installation plan of the body.
Is it single-phase or three-phase?
It is single-phase. Check the voltage of the PCB and protections with the installer.
Can I buy it with installation?
The price includes VAT and shipping costs. Installation is quoted separately based on location, route, and necessary work. Check availability and lead time before placing the order.

Services for your air conditioning