TCL duct set: range illustration, not to scale

TCL ducted air conditioning M18D1W2 · 4.70 kW

857,65 €VAT included

4042 frigorías/h for ducted air conditioning. Interior height of 200 mm and single-phase power supply.

1/4″ / 3/8″ · Monofásica · body 200 mm de alto · precarga 5 m What to consider

VAT and shipping included. Installation not included. Availability and delivery time to be confirmed.

Availability to be confirmed
Components and supply

What does TCL M18D1W2 include?

Duct set 1×1: components grouped according to the TCL table.

ModelComponentSupply scope
MN18DW2Ducted indoor unit
920 × 200 × 490 mm · 18.0 kg
1 included
MT1813Outdoor unit
853 × 602 × 349 mm · 30 kg
1 included

The reference and supply of the control unit are confirmed in the quote. Installation, piping, supports, wiring, ducts, and grilles, as well as commissioning, are budgeted separately.

Cover: illustrative composition of the range, not to scale. The official photographs of the indoor unit are shared among capacities. Check the references and dimensions of this set.

Guide

What to check before installing TCL M18D1W2

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Reserve space for the interior of 200 mm in height, its connections, the drainage, and the maintenance access points. The duct network and the grilles are sized separately.
  2. Tubería 1/4″ / 3/8″. Precarga para 5 m; recorrido máximo 25 m y desnivel 10 m. La carga adicional por metro debe comprobarse en el manual exacto. El instalador debe contrastar placa y revisión antes de intervenir.
  3. The set is single-phase. The installer will check the voltage of the PCB, the protections, the wiring, and the ventilation distances.
  4. The reference and the supply of the control are confirmed in the budget.
Technical data

TCL M18D1W2

Brand
TCL
Model and composition
TCL M18D1W2
Supply scope
MN18DW2 + MT1813
Installation
Not included
Availability and transport
VAT and shipping included. Installation not included. Confirm availability and delivery time.

Specifications and dimensions of the model

Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.

Set
M18D1W2
Set and power supply
Indoor unit
MN18DW2
Set and power supply
Outdoor unit
MT1813
Set and power supply
Type
Ducts 1×1 · cooling and heating
Set and power supply
Power supply
220 V · single-phase
Set and power supply
Nominal power in cold conditions
4.70 kW
Power and efficiency
Approximate nominal cooling capacity
4042 frigorías/h
Power and efficiency · Conversion: kW × 860.
Nominal heat output
4.70 kW
Power and efficiency
Energy class in cold
A++
Power and efficiency
Energy class in heating
A+
Power and efficiency
Interior · width × height × depth
920 × 200 × 490 mm
Measures to prepare the installation
Net internal weight
18.0 kg
Measures to prepare the installation
Net external weight
30 kg
Measures to prepare the installation
Exterior · width × height × depth
853 × 602 × 349 mm
Medidas para preparar la instalación · TCL, ficha del modelo actual; coincide con la tabla de conductos MT1813.
Pipe · liquid / gas
1/4″ / 3/8″
Pipe and refrigerant
Refrigerant
R32
Pipe and refrigerant
Factory published load
0.96 kg
Pipe and refrigerant · Catalog data; check the revision plate provided.
SEER
6,1
Eficiencia, consumo y circulación de aire
SCOP · average climate
4
Eficiencia, consumo y circulación de aire
Consumo nominal en frío
1480 W
Eficiencia, consumo y circulación de aire · Potencia eléctrica nominal, no capacidad térmica.
Consumo nominal en calor
1390 W
Eficiencia, consumo y circulación de aire · Potencia eléctrica nominal, no capacidad térmica.
External sound power
65 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora.
Potencia sonora interior · S/H/M/L/silencio
56/53/48/42/38 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora.
Caudal de aire interior
850 m³/h
Eficiencia, consumo y circulación de aire
Presión estática externa nominal
25 Pa
Eficiencia, consumo y circulación de aire
Presión estática externa regulable
0-100 Pa
Eficiencia, consumo y circulación de aire
Tubería cubierta por la precarga
5 m
Límites para preparar la instalación · Catálogo TCL 2026 Portugal, página PDF 11; no es el recorrido máximo.
Maximum range
25 m
Límites para preparar la instalación · Tabla oficial TCL Europa para esta referencia.
Maximum slope
10 m
Límites para preparar la instalación · Entre las unidades interior y exterior.
Before purchasing
  • Data from the linked documentation for the indicated reference. Check the PCB and the installation manual of the supplied revision before sizing gaps, connections, or refrigerant charge. The images are not assembly diagrams.

Documentation

Frequently Asked Questions

Questions about TCL M18D1W2

How many frigorías does the TCL M18D1W2 have?
Approximately 4042 frigorías/h, based on 4.70 kW nominal in cooling. This is thermal capacity, not electrical consumption.
What does the set include?
Indoor duct unit MN18DW2, outdoor unit MT1813. The reference and supply of the remote control are confirmed in the budget.
What pipe do you need?
Tubería 1/4″ / 3/8″. Precarga para 5 m; recorrido máximo 25 m y desnivel 10 m. La carga adicional por metro debe comprobarse en el manual exacto. El instalador debe contrastar placa y revisión antes de intervenir.
How much false ceiling do you need?
The body is 200 mm high. The mounting space, drainage, connections, and service must be added; this figure should not be taken as the minimum false ceiling.
Is it single-phase or three-phase?
It is single-phase. Check the voltage of the PCB and protections with the installer.
Can I buy it with installation?
The price includes VAT and shipping costs. Installation is quoted separately based on location, route, and necessary work. Check availability and lead time before placing the order.

Services for your air conditioning

TCL ducted air conditioning M18D1W2 · 4.70 kW